Thermador PRG305WH Installation Instructions - Page 26
Normal for Natural Gas
View all Thermador PRG305WH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
3. Repeat the ignition and flame test for each rangetop burner. Flame characteristics Yellow flames: Further Adjustment is required. Yellow tips on outer cones: Normal for LP Gas Soft blue flames: Normal for Natural Gas The burners that feature XLO®, cause the flame to cycle on and off when the knob is set to the XLO function. This is normal operation. When flame is properly adjusted: • There should be a flame at each burner port. • There should be no air gap between the flame and burner port. Call Thermador service if: • Any of the burners do not light. • Any of the burners continue to burn yellow. If the flame is completely or mostly yellow, verify that the regulator is set for the correct fuel. After adjustment, retest. Some orange-colored streaking is normal during the initial start-up. Allow unit to operate 4-5 minutes and re-evaluate before making adjustments. Page. 24