Thermador T36IB70NSP Design Guide - Freedom Refrigeration - Page 12
Freedom, Collection, Freedom Refrigeration - specifications
View all Thermador T36IB70NSP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
FREEdOM REFRIGERATION FREEdOM® COLLECTION PLANNING INFORMATION ELECTRICAL SPECIFICATIONS The appliance comes with a 3-wire power supply cord. UL listed in the USA. The appliance requires a 3-wire receptacle that is fitted with a 10 Amp fuse or higher. Refer to the following table for max load details. APPLIANCE MAX LOAd 24-Inch Fresh Food Column 1.5 Amps 30-Inch Fresh Food Column 1.5 Amps 18-Inch Freezer Column* 3.06 Amps 24-Inch Freezer Column* 3.70 Amps 30-Inch Freezer Column* 4.20 Amps 36-Inch 2-Door Bottom Freezer* 4.9 Amps 36-Inch French Door Bottom Freezer 4.9 Amps 18-Inch Wine Preservation Column 0.81 Amps 24-Inch Wine Preservation Column 0.90 Amps *Including ice maker The receptacle must be installed by a licensed electrician only. For the installation position of the receptacle refer to diagram in Electrical Location. IMPORTANT A 4-conductor cord shall be used when the appliance is installed in an area where the local codes do not permit grounding through the neutral. Power supply cord must be replaced by a licensed electrician only. AddITIONAL GROUNdING PROCEdURE Some local regulations may require a separate ground. In such cases, the required accessory ground wire, clamp and screw must be purchased separately. Never ground the appliance to plastic plumbing lines, gas lines or water pipes. GROUNdING INSTRUCTION This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for the electric current. WARNING Improper connection of the equipment grounding conductor may result in electric shock. Have the appliance checked by a qualified electrician or service technician if you are in doubt as to whether the appliance has been properly grounded. WATER LOCATION A cold water connection is required for appliances which feature an ice maker or an ice water dispenser. The water pressure must be between 40 and 120 p.s.i. (2.758.25 bar). The installation must comply with local plumbing regulations. A separate shut-off valve must be installed for the appliance water connection. The shut-off valve for the water connection must not be behind the appliance. It is recommended to place the shut-off valve directly next to the appliance (base unit) or in another easily accessible location. When installing the water connection, observe the permitted installation areas for the water supply line. The supply line can be located at the side on the right (a), at the side on the left (b), or underneath (c). ELECTRICAL LOCATION SPLIT COLUMN INSTALLATION 18-Inch 24-Inch 30-Inch X 18" 24" 30" (457mm) (610mm) (762mm) Y 9" 12" 15" (229mm) (305mm) (381mm) SIdE-BY-SIdE INSTALLATION 1.800.735.4328 | THERMADOR.COM 221