Step 7: Mount Integral Blower or, Outlet Duct Transition for Remote or, Inline Blower
View all Thermador UCVM36FS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Step 7: Mount Integral Blower or Outlet Duct Transition for Remote or Inline Blower Integral Blower (see Figures 9 and 11 for further detail): Y A. Attach blower in front of round exhaust outlet with 4-6 (depending on configuration) #8 sheetmetal screws. Y B. Feed cord from blower through strain relief. Y C. Secure strain relief with screws. Y D. Attach strain relief to downdraft near junction box. Y E. Connect cord to downdraft at 6 pin connector. Y F. Connect blower to ductwork. Step 7: Mount Integral Blower or Outlet Duct Transition for Remote Blower Integral Blower VTN600CV2C (see Figures 10 and 12 for further detail): Y G. Place the cooktop in countertop opening with the rear edge of cooktop overlapping the front edge of the vent. Make sure rear edge of cooktop does not bind against front of snorkel. Follow the manufacturer's installation Instructions for installing gasket strips, protective heat tape (if required), securing the cooktop to the countertop and making the cooktop electrical and/or gas connections. Note: Check boxes as tasks are completed.