Thermador VCI29CS Installation Instructions - Page 6
Preparation
View all Thermador VCI29CS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Installation Preparation Electrical Requirements Mounting Requirements The unit requires a 120V AC, 60Hz. 15A branch circuit. For future service, install the outlet in an easily accessible location. The unit must be mounted to the surrounding housing. See "General Information" on page 3 for suggestions for determining hood height. For best results, install the unit as far up in the housing or hood as possible. This will improve the function of the appliance. When calculating the load for the housing support system, be sure to include the weight of the ventilation unit. See "Ventilation Unit Weight" on page 4. for unit weight by model. Table 1: Ventilation Unit Weight Size Min. Weight 21" (53 cm) 29" (73 cm) 18 1/4 lbs. (8.3 kg) 19 lbs. (8.7 kg) For proper performance, the housing must cover the entire cooking surface. Build housing to correspond with Figure 7: Housing Cutout Dimensions - 20 7/8" (53 cm) models or Figure 8: Housing Cutout Dimensions - 28 3/4" (73 cm) models. 5/8" (15 mm) min. (133257./38"mm) 5/8" (15 mm) min. 5/8" (16 mm) (500.139m5m/8)" Figure 7: Housing Cutout Dimensions - 20 7/8" (53 cm) models English 4