Tissot T-TOUCH EXPERT SOLAR TONY PARKER 2014 User Manual - Page 10
Sleep Standby Mode >, Meteo Weather >
View all Tissot T-TOUCH EXPERT SOLAR TONY PARKER 2014 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
T-TOUCH SOLAR E84 SLEEP (STANDBY MODE) > SETTING Standby mode is a battery saving mode. All the functions are deactivated, with only the time & date counters updated. This mode economises the battery when the watch is not being worn. IMPORTANT: Calibrate the altitude or relative pressure by exiting standby mode, in order to obtain the correct altimetric and barometric values. or or Activate standby mode Switch to standby mode after 5 seconds Beep every second a) The watch is in standby or Back to time & date mode b) / : stop the count, the watch does not switch to standby mode. Back to time & date mode METEO (WEATHER) > READING In meteo mode, the hands are superimposed to indicate the weather trend. 1 sec. Activate glass Relative pressure display in hPa Absolute pressure display in hPa METEO (WEATHER) > RELATIVE PRESSURE PRESETTING Setting this pressure changes the altitude displayed. The possible relative pressure is deliberately limited between 950 hPa and 1100 hPa. 2 sec. or or Setting mode www.tissot.ch : up 1 hectopascal : down 1 hectopascal 10/21 Validate setting 154_EN