Toshiba A105-S2716 Maintenance Manual - Page 58
Status, Disk Controller Test unexpected interrupt Failed - how to restore disk
View all Toshiba A105-S2716 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
2.5 2.5-inch HDD 2 Troubleshooting Procedure 4 Test Program Check Run the HDD test program stored on the maintenance test program disk for all test items. See Chapter 3 for details on how to use the test program. If an error is detected during the HDD test, an error code and status will be displayed. The error codes and their status names are listed in Table 2-1. If an error code is not generated and the problem still exists, go to Procedure 5. Table 2- 1 HDD error code and status Code 1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 Status Get Parameter Fail ! Read Old Data Error Write Pattern Error Read Back Data Error Data Compare Error Restore Data Error Read Verify Error Seek Error Disk Controller Self Test Failed Disk Controller Test unexpected interrupt Failed Disk Controller action Test Failed Disk dos not support SMART Disk read attribute threshold error Disk read attribute value error Disk SMART attribute value error Satellite A100/A105 / TECRA A7 Maintenance Manual 2-15