Toshiba PSA10C-035WM Maintenance Manual - Page 60
Main Battery, Second Battery, S3V output, 1R5-C1V output P61, Error code, Meaning
View all Toshiba PSA10C-035WM manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
2.3 Power Supply Troubleshooting 2 Troubleshooting Procedures Main Battery Error code Meaning 21h Main battery charge current is over 6.60A. 22h Main battery discharge current is over 0.5A when there is no load. 23h Main battery charge current is over 3.9A when AC adapter is not connected. 24h Abnormal current has been sensed. 25h Main battery charge current is over 0.3A. Second Battery Error code Meaning 31h Second battery charge current is over 6.60A. 32h Second battery discharge current is over 0.5A when there is no load. 33h Second battery charge current is over 3.9A. when AC adapter is not connected. 34h Abnormal current has been sensed. 35h Second battery charge current is over 0.3A. S3V output Error code Meaning 40h S3V voltage is 3.14V or less when the computer is powered on/off. 45h S3V voltage is 3.14V or less when the computer is booting up.(CV support) 1R5-C1V output (P61) Error code Meaning 50h 1R5-C1V voltage is over 1.80V when the computer is powered on/off. 51h 1R5-C1V voltage is 1.275V or less when the computer is powered on. 52h 1R5-C1V voltage is 1.275V or less when the computer is booting up. 53h 1R5-C1V voltage is 1.275V while the computer is suspended. 54h 1R5-C1V voltage is abnormal while the computer is shutdown. (CV support) 55h 1R5-C1V voltage is 1.275V or less when the computer is booting up. (CV support) Satellite A10/TECRA A1/Satellite Pro A10 Maintenance Manual (960-445) 2-9