Toshiba TDP-XP2U User Manual - Page 38
Lamp replacement Continued, Mount the new lamp., Replace the lamp cover., Reset the lamp time.
UPC - 883974099443
View all Toshiba TDP-XP2U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Lamp replacement (Continued) 5 Mount the new lamp. 5 2 Align the orientation, press down the new lamp until the bottom is reached, and lock in place using the two lamp locking screws. 1 6 Replace the lamp cover. Align the cover, and press it in, then tighten the screws loosened in step 3 until the lamp cover is no longer loose. (Be sure to replace the lamp cover.) 7 Reset the lamp time. See the lamp's manual for instructions on resetting the lamp time. Notes and Precautions • The [Lamp time] item in the Status display menu indicates the time of lamp use (as a rough guide). p.35 • It is recommended that the lamp be replaced after 3,000 hours of use.When [Lamp time] reaches 3,000 hours, a message will appear. (After 3,000 hours, the message will appear when the power is first turned on after each 100 hour period of use.) This display disappears when you press the button. • Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the projector may fail to be powered on or the lamp may fail to come on. • Always replace the lamp with a new one. • The lamp is made out of glass. Do not touch the glass surface with your bare hands, bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.) Used Lamps This projector's lamps contain trace amounts of environmentally harmful inorganic mercury. Be careful not to break used lamps, and dispose of them in accordance with local regulations. 38