Tripp Lite 9PX10KSP Eaton 9PX UPS 700-3000 VA 2U Owners Manual - Page 40
Silencing the alarm, Service and support, CE compliance contact
View all Tripp Lite 9PX10KSP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
7. Troubleshooting UPS overtemperature LED is On. 1 beep every 3 seconds. The UPS does not start. BaLtotaedrynroetpplaocweemreendt 4-% years bat1te0r0y% ! R-keWplaceme1n0t0ismin -kreVcAommend1eEdBM OK The UPS internal temperature is too high or a fan has failed. At the warning level, the UPS generates the alarm but remains in the current operating state. If the temperature rises another 10°C, the UPS transfers to Bypass mode or shuts down if Bypass is unusable. The input source is not connected correctly. The Remote Power Off (RPO) switch is active or the RPO connector is missing. After 4 years of operation, the UPS will provide a battery replacement notification reminding you that your batteries are nearing the end of their useful life. If the UPS transferred to Bypass mode, the UPS will return to normal operation when the temperature drops 5°C below the warning level. If the condition persists, shut down the UPS. Clear vents and remove any heat sources. Allow the UPS to cool. Ensure the airflow around the UPS is not restricted. Restart the UPS. If the condition continues to persist, contact your service representative. Check the input connections. If the UPS Status menu displays the "Remote Power Off" notice, inactivate the RPO input. See "6.3 When to replace batteries" 7.2 Silencing the alarm Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes, the alarm beeps again, overriding the previous alarm silencing. 7.3 Service and support If you have any questions or problems with the UPS, call your Local Distributor or your local service representative and ask for a UPS technical representative. Please have the following information ready when you call for service: • Model number • Serial number • Firmware version number • Date of failure or problem • Symptoms of failure or problem • Customer return address and contact information If repair is required, you will be given a Returned Material Authorization (RMA) number. This number must appear on the outside of the package and on the Bill Of Lading (if applicable). Use the original packaging or request packaging from the Help Desk or distributor. Units damaged in shipment as a result of improper packaging are not covered under warranty. A replacement or repair unit will be shipped, freight prepaid for all warrantied units. For critical applications, immediate replacement may be available. Call the Help Desk for the dealer or distributor nearest you. 7.4 CE compliance contact • Eaton I.F. SAS - 110 Rue Blaise Pascal - 38330 Montbonnot St Martin - France. Page 40 9PX 1-3 KVA US_EN