Tripp Lite B055-001-USB Quick Start Guide for B055-001-SER 932934 - Page 2

Configuration, Operation, Warranty, Connector Pinout

Page 2 highlights

Configuration 3. In the Properties section, drop down each of the lists to select the port property values that match the ones used by the connected serial console device. The port property settings that the B055-001-SER support are listed in the following table: Setting Meaning Bits per second (Baud Rate) This sets the port's data transfer speed. Choices range from 300 to 38400 (drop down list shows them all). Set the rate to match the Baud Rate setting of the serial console device. The default is 9600. If the Baud Rate is set to 9600, FLOW CONTROL must be used. Note: FLOW CONTROL is not supported by all devices. For these devices, 9600 is the max supported Baud Rate. Data Bits This sets the number of bits used to transmit one character of data. Choices are 7 or 8. Set this to match the data bit setting of the serial console device. The default is 8 (this is the default for the majority of serial console devices). Parity This bit checks the integrity of the transmitted data. Choices are: None, Odd or Even. Set this to match the parity setting of the serial console device. The default is Odd. Stop Bits This indicates that a character has been transmitted. Set this to match the stop bit setting of the serial console device. Choices are 1 or 2. The default is 1 (this is the default for the majority of serial console devices). Flow Control This allows you to choose how the data flow will be controlled. Choices are None, Hardware and XON/XOFF. Set this to match the flow control setting of the serial console device. The default is None. Access Mode This allows you to set the serial console device's access mode. Choices are Share, Occupy and Exclusive. The default is Share. (See the B064-Series manual for details on access modes.) 4. When you have finished making all of your selections, click Save. Operation To operate the device connected to the port, simply double click the port in the Port Access page. After you switch to the port, issue the command that calls up the device. Connector Pinout DB9 (Female) 2 3 5 7 8 4 6 SHIELD GND Warranty WARRANTY REGISTRATION Visit www.tripplite.com/warranty today to register the warranty for your new Tripp Lite product. You'll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product!* * No purchase necessary. Void where prohibited. Some restrictions apply. See website for details. Warning! Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union) Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when customers buy new electrical and electronic equipment from Tripp Lite they are entitled to: • Send old equipment for recycling on a one-for-one, like-for- like basis (this varies depending on the country) • Send the new equipment back for recycling when this ultimately becomes waste Tripp Lite follows a policy of continuous improvement. Product specifications are subject to change without notice. 1111 W. 35th Street, Chicago, Il 60609 USA • www.tripplite.com/support 13-01-153 • 93-2934_revB 13-01-153-932934-revB.indd 2 1/30/2013 3:28:34 PM

  • 1
  • 2

Configuration
3. In the
Properties
section, drop down each of the lists to select the port property values
that match the ones used by the connected serial console device. The port property
settings that the B055-001-SER support are listed in the following table:
Setting
Meaning
Bits per
second
(Baud Rate)
This sets the port’s data transfer speed. Choices range from 300 to 38400 (drop down list shows
them all). Set the rate to match the Baud Rate setting of the serial console device. The default is
9600. If the Baud Rate is set to 9600,
FLOW CONTROL
must be used.
Note:
FLOW CONTROL
is not supported by all devices. For these devices, 9600 is the max supported Baud Rate.
Data Bits
This sets the number of bits used to transmit one character of data. Choices are 7 or 8. Set this
to match the data bit setting of the serial console device. The default is 8 (this is the default for
the majority of serial console devices).
Parity
This bit checks the integrity of the transmitted data. Choices are: None, Odd or Even.
Set this to match the parity setting of the serial console device. The default is Odd.
Stop Bits
This indicates that a character has been transmitted. Set this to match the stop bit setting of the
serial console device. Choices are 1 or 2. The default is 1 (this is the default for the majority of
serial console devices).
Flow Control
This allows you to choose how the data flow will be controlled. Choices are None, Hardware and
XON/XOFF. Set this to match the flow control setting of the serial console device. The default is None.
Access Mode
This allows you to set the serial console device’s access mode. Choices are Share, Occupy and
Exclusive. The default is Share. (See the B064-Series manual for details on access modes.)
4. When you have finished making all of your selections, click Save.
Operation
To operate the device connected to the
port, simply double click the port in
the Port Access page. After you switch
to the port, issue the command that calls
up the device.
13-01-153 • 93-2934_revB
1111 W. 35th Street, Chicago, Il 60609 USA • www.tripplite.com/support
Warranty
Connector Pinout
DB9 (Female)
2
3
5
7
8
4
6
SHIELD GND
WARRANTY REGISTRATION
Visit www.tripplite.com/warranty today to register the warranty for
your new Tripp Lite product. You’ll be automatically entered into a
drawing for a chance to win a FREE Tripp Lite product!*
* No purchase necessary. Void where prohibited.
Some restrictions apply. See website for details.
Warning!
Use of this equipment in life support applications where failure of
this equipment can reasonably be expected to cause the failure
of the life support equipment or to significantly affect its safety or
effectiveness is not recommended. Do not use this equipment in
the presence of a flammable anesthetic mixture with air, oxygen
or nitrous oxide.
WEEE Compliance Information for Tripp Lite
Customers and Recyclers (European Union)
Under the Waste Electrical and Electronic Equipment (WEEE)
Directive and implementing regulations, when customers buy
new electrical and electronic equipment from Tripp Lite they are
entitled to:
• Send old equipment for recycling on a one-for-one, like-for-
like basis (this varies depending on the country)
• Send the new equipment back for recycling when this
ultimately becomes waste
Tripp Lite follows a policy of continuous improvement. Product
specifications are subject to change without notice.
13-01-153-932934-revB.indd
2
1/30/2013
3:28:34 PM