Tripp Lite B098048 Owners Manual for B093- B097- and B098-Series Console Serve - Page 80
Always-On Dial-Out
View all Tripp Lite B098048 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 80 highlights
5. Firewall, Failover and OOB Access 5.3.1 Always-On Dial-Out With firmware version 3.4 (and later), the console server modem can be configured for out-dial to be always on, with a permanent external dial-up ppp connection. • Select the System: Dial menu option and check Enable Dial-Out to allow outgoing modem communications. • Select the Baud Rate and Flow Control that will communicate with the modem. • In the Dial-Out Settings - Always On Out-of-Band field, enter the access details for the remote PPP server to be called. Override DNS is available for PPP Devices, such as modems. Override DNS allows the use of alternate DNS servers from those provided by your ISP. For example, an alternative DNS may be required for OpenDNS used for content filtering. •To enable Override DNS, check the Override Returned DNS Servers box. Enter the IP of the DNS servers into the spaces provided. 80