Tripp Lite OMNIVS1000 Owner's Manual for OmniVS UPS 932712 - Page 4

Quick Installation, Basic Operation - used

Page 4 highlights

200710045 93-2712 Omni VS Series update.qxd 12/21/2007 10:40 AM Page 4 Quick Installation optional These connections are optional. The UPS will function properly without these connections. 1 Phone Line/Network Line Surge Suppression The UPS has jacks which protect against surges over a phone line or network data line. Using telephone cords or network data cables as appropriate, connect the wall jack to the UPS jack marked "IN." Connect equipment to the UPS jack marked "OUT." Make sure the equipment connected to the UPS jacks is also protected against surges on the AC line. NOTE: Tel/DSL/Ethernet (RJ-45) jacks not compatible with PoE 1 (Power over Ethernet) applications. 2 USB Communications Use a USB cable to connect the computer's USB port to the USB port of the UPS. Download the PowerAlert UPS monitoring software program appropriate for the computer's operating system from www.tripplite.com/software/ and install it. NORM DELAY NORM DELAY 3 External Battery Connection 2 (Select Models) All UPS models come with a robust internal battery system; NORM DELAY select models feature connectors that accept an optional external battery pack (sold separately from Tripp Lite) to provide additional runtime. Adding an external battery will increase recharge time as well as runtime. See battery pack owner's manual for complete installation instructions. Make sure cables are fully inserted into their connectors. Small sparks may result during battery connection; this is normal. Do not connect or disconnect battery pack when the UPS is running on battery power. 3 Basic Operation Buttons Switch the Operating Mode: While the UPS is plugged into a live AC outlet, ON/OFF Button: press the ON/OFF button and hold it until the UPS beeps (about 2 seconds) to toggle between ON and OFF. • ON Mode: ENABLES battery backup. UPS Conditions: The UPS charges the battery and supplies power to the outlets while receiving utility line power. The " " indicator light will illuminate. If utility power fails, the UPS provides power from battery. Cold-Start: Cold start the UPS to use it as a stand-alone power source when utility power is not present (if the UPS battery is charged). To cold start the UPS, press and hold the ON/OFF button until the UPS beeps (about 2 seconds), then release it. The " " indicator will illuminate and AC power inverted from stored battery power will be provided to the outlets. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

4
These connections are optional. The UPS will function properly without these connections.
Phone Line/Network Line Surge
Suppression
The UPS has jacks which protect against surges over a
phone line or network data line.
Using telephone cords or network data cables as
appropriate, connect the wall jack to the UPS jack marked
“IN.” Connect equipment to the UPS jack marked “OUT.”
Make sure the equipment connected to the UPS jacks is
also protected against surges on the AC line.
NOTE:
Tel/DSL/Ethernet (RJ-45) jacks not compatible with PoE
(Power over Ethernet) applications.
USB Communications
Use a USB cable to connect the computer’s USB port to the
USB port of the UPS. Download the PowerAlert UPS
monitoring software program appropriate for the computer’s
operating system from www.tripplite.com/software/ and
install it.
External Battery Connection
(Select Models)
All UPS models come with a robust internal battery system;
select models feature connectors that accept an optional
external battery pack (sold separately from Tripp Lite) to
provide additional runtime. Adding an external battery will
increase recharge time as well as runtime. See battery pack
owner’s manual for complete installation instructions. Make
sure cables are fully inserted into their connectors. Small
sparks may result during battery connection; this is normal.
Do not connect or disconnect battery pack when the UPS is
running on battery power.
2
1
Quick Installation
optional
3
Basic Operation
3
Switch the Operating Mode:
While the UPS is plugged into a live AC outlet,
press the
ON/OFF
button and hold it until the UPS beeps (about 2 seconds) to
toggle between
ON
and
OFF.
• ON Mode:
ENABLES battery backup.
UPS Conditions:
The UPS charges the
battery and supplies power to the outlets while receiving utility line power. The
” indicator light will illuminate. If utility power fails, the UPS provides
power from battery.
Cold-Start:
Cold start the UPS to use it as a stand-alone power source when
utility power is not present (if the UPS battery is charged). To cold start the
UPS, press and hold the
ON/OFF
button until the UPS beeps (about 2
seconds), then release it. The “
” indicator will illuminate and AC power
inverted from stored battery power will be provided to the outlets.