Tripp Lite SU10000RT3UPM Owner's Manual for SmartOnline 8kVA-10kVA UPS 932897 - Page 14

Normal Operation, UPS Setup Menu

Page 14 highlights

Operation (continued) Normal Operation During normal operation, the first line of your LCD Display shows which operating mode your UPS is in: Online, Economy, On Battery, or Bypass. Online mode: The UPS provides AC power while utility power is available and switches to On Battery mode instantly (zero transfer time) if AC power is interrupted. Economy mode: The UPS provides AC power at high efficiency while utility power is within +/- 10% rated AC input voltage and switches to On Battery mode (zero transfer time) if AC power is interrupted. Industrial mode: If the UPS detects an output voltage fluctuation more than 5 ms, the UPS will transfer to Bypass mode, returning to Online mode when the output is back to normal. On Battery mode: The UPS provides AC power from battery backup so long as battery power lasts. It switches back to Online or Economy mode if utility power is available and shuts down if it runs out of battery power. Bypass mode: The UPS provides AC power while utility power is available. The UPS shuts down if AC power is interrupted. Parallel mode: The UPS can provide redundancy up to 10K or power up to 20K. Refer to your Paralleling Kit manual for more information. The second line of the LCD Display shows basic power conditions. Push the SCROLL buttons to browse through these basic power conditions in the sequence shown below.       LOAD LEVEL 00.00KW / 000%  LOAD LEVEL 00.00KVA / 000%  INPUT VOLTAGE 000V / 00.0Hz  BYPASS VOLTAGE 000V / 00.0Hz  OUTPUT VOLTAGE 000V / 00.0Hz  BATTERY CAPACITY 000V / 000%  ON-LINE 10KVA V00 CV01      BATTERY CAPACITY 000V / 000%  LOAD LEVEL 00.00KW / 000%  LOAD LEVEL 00.00KVA / 000%  BYPASS VOLTAGE 000V / 00.0Hz  OUTPUT VOLTAGE 000V / 00.0Hz  ON-LINE 10KVA V00 CV01 UPS Setup Menu Press the UPh and DOWNi buttons simultaneously for 3 seconds until the SETUP MENU screen appears as seen below: UPS SETUP EXIT ENTER Press the UPh button to enter Set Up Mode. To enter Set Up Mode, you will be required to enter a password. PASSWORD : 0000 ENT DOWN UP XX Numbers increase or decrease by 1 when pressing the UPh and DOWNi buttons (0-9). Scroll to select the first number, then press the ON button. This saves the first number and moves on to the next in the sequence. The password range is 0000-9999 and should be changed by the administrator. The DEFAULT password is 1234. 14 201102160 93-2897.indb 14 3/30/2011 9:30:52 AM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

14
Operation (continued)
Normal Operation
During normal operation, the first line of your LCD Display shows which operating mode your UPS is in: Online, Economy, On Battery, or Bypass.
Online mode:
The UPS provides AC power while utility power is available and switches to On Battery mode instantly (zero transfer time) if AC
power is interrupted.
Economy mode:
The UPS provides AC power at high efficiency while utility power is within +/- 10% rated AC input voltage and switches to On
Battery mode (zero transfer time) if AC power is interrupted.
Industrial mode:
If the UPS detects an output voltage fluctuation more than 5 ms, the UPS will transfer to Bypass mode, returning to Online mode
when the output is back to normal.
On Battery mode:
The UPS provides AC power from battery backup so long as battery power lasts. It switches back to Online or Economy mode
if utility power is available and shuts down if it runs out of battery power.
Bypass mode:
The UPS provides AC power while utility power is available. The UPS shuts down if AC power is interrupted.
Parallel mode:
The UPS can provide redundancy up to 10K or power up to 20K. Refer to your Paralleling Kit manual for more information.
The second line of the LCD Display shows basic power conditions. Push the SCROLL buttons to browse through these basic power conditions in
the sequence shown below.
UPS Setup Menu
Press the UP
h
and DOWN
i
buttons simultaneously for 3 seconds until the SETUP MENU screen appears as seen below:
Press the UP
h
button to enter Set Up Mode.
To enter Set Up Mode, you will be required to enter a password.
Numbers increase or decrease by 1 when pressing the UP
h
and DOWN
i
buttons (0-9). Scroll to select the first number, then press the ON
button. This saves the first number and moves on to the next in the sequence. The password range is 0000-9999 and should be changed by the
administrator. The DEFAULT password is 1234.
UPS
SETUP
EXIT
ENTER
PASSWORD :
0000
ENT
DOWN
UP
XX
LOAD LEVEL
00.00KW / 000%
BATTERY CAPACITY
000V / 000%
LOAD LEVEL
00.00KVA / 000%
LOAD LEVEL
00.00KW / 000%
INPUT VOLTAGE
000V / 00.0Hz
LOAD LEVEL
00.00KVA / 000%
BYPASS VOLTAGE
000V / 00.0Hz
BYPASS VOLTAGE
000V / 00.0Hz
OUTPUT VOLTAGE
000V / 00.0Hz
OUTPUT VOLTAGE
000V / 00.0Hz
BATTERY CAPACITY
000V / 000%
ON-LINE 10KVA
V00
CV01
ON-LINE 10KVA
V00
CV01
201102160
93-2897.indb
14
3/30/2011
9:30:52 AM