Tripp Lite SU30K3/3XR5 Owner's Manual for SmartOnline 3-Phase 20kVA & 30kV - Page 18

Model: SU30K3/3, Model: SU30K3/3XR5

Page 18 highlights

9. Specifications (continued) Model: SU30K3/3 Model: SU30K3/3XR5 Input Input Voltage 120/208V AC, 3ø, 4 Wire (plus ground), wye Input Input Voltage 120/208V AC, 3ø, 4 Wire (plus ground), wye Input Frequency Voltage Correction Range 60 Hz ± 3 Hz 96-144/166-250V AC Input Frequency Voltage Correction Range 60 Hz ± 3 Hz 96-144/166-250V AC Input Current (Per Phase, On-Line) 90A Input Current (Per Phase, On-Line) 90A Inrush Current Power Factor (Full Load) 0.95 Inrush Current Power Factor (Full Load) 0.95 Efficiency (Full Load/On-Line) >89% Efficiency (Full Load/On-Line) >89% Circuit Breaker Input Bypass Circuit Breaker 100A (3p) 100A (3p) Circuit Breaker Input Bypass Circuit Breaker 100A (3p) 100A (3p) Output Output VA Watts (Power Factor: 0.8) 30000 24000 VA Watts (Power Factor: 0.8) 30000 24000 Waveform (On-Line) Sinewave Waveform (On-Line) Sinewave Waveform (On-Battery) Output Voltage (RMS) Sinewave 120/208V AC, 3ø, 4 Wire (plus ground), wye Waveform (On-Battery) Output Voltage (RMS) Sinewave 120/208V AC, 3ø, 4 Wire (plus ground), wye Output Frequency 60 Hz (± 0.1 Hz on battery) Output Frequency 60 Hz (± 0.1 Hz on battery) Voltage Regulation Max. Harmonic Distortion (Non-Linear Full Load) ±2%

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

201008010 • 932624-EN
18
Model: SU30K3/3
Input
Input Voltage
120/208V AC, 3ø, 4 Wire (plus ground), wye
Input Frequency
60 Hz ± 3 Hz
Voltage Correction Range
96-144/166-250V AC
Input Current (Per Phase, On-Line)
90A
Inrush Current
<300A
Power Factor (Full Load)
>0.95
Efficiency (Full Load/On-Line)
>89%
Circuit Breaker
100A (3p)
Input Bypass Circuit Breaker
100A (3p)
Output
VA
30000
Watts (Power Factor: 0.8)
24000
Waveform (On-Line)
Sinewave
Waveform (On-Battery)
Sinewave
Output Voltage (RMS)
120/208V AC, 3ø, 4 Wire (plus ground), wye
Output Frequency
60 Hz (± 0.1 Hz on battery)
Voltage Regulation
±2%
Max. Harmonic Distortion
(Non-Linear Full Load)
<5%
Overload Capabilities
102% (continuous), 102%~125% (1 min.),
125%~150% (30 sec.),
150% (2 sec.)
Short Circuit Capability
250A
Crest Factor
3:1
Battery
Battery Type
Sealed, Lead Acid, 240V DC, 9AH
Battery Pack Quantity
Three Packs (20 12V DC Batteries per pack)
Protection
Six UL-recognized 30A 600VDC rated cartridge
fuses (two per battery pack) and fuse block
(1 per battery pack)
Typical Backup Time (Half Load)
13 min. +
Typical Backup Time (Full Load)
5 min. +
Operation
On-Line Transfer Time
(Line to Battery, Battery to Line)
0 ms
Audible Noise (Full Load @ 1 meter)
<65 dBA
Indicators
Includes an LCD Display and LEDs (AC Line In, Bypass Line In, AC to DC, DC to AC,
AC Output, Battery Back-Up, Bypass).
Communications
Includes an RS-232 DB9 female connector, an AS-400 DB9 female connector, a dry contact
DB9 female connector and an accessory slot.
Connections
Input Terminal Block
100A
Output Terminal Block
100A
Physical Specifications
Unit Dimensions (H x W x D)
35.3 x 19.3 x 36 in.
Unit Weight
662 lb.
Shipping Dimensions (H x W x D)
43 x 28 x 44.5 in.
Shipping Weight
750 lb.
Model: SU30K3/3XR5
Input
Input Voltage
120/208V AC, 3ø, 4 Wire (plus ground), wye
Input Frequency
60 Hz ± 3 Hz
Voltage Correction Range
96-144/166-250V AC
Input Current (Per Phase, On-Line)
90A
Inrush Current
<300A
Power Factor (Full Load)
>0.95
Efficiency (Full Load/On-Line)
>89%
Circuit Breaker
100A (3p)
Input Bypass Circuit Breaker
100A (3p)
Output
VA
30000
Watts (Power Factor: 0.8)
24000
Waveform (On-Line)
Sinewave
Waveform (On-Battery)
Sinewave
Output Voltage (RMS)
120/208V AC, 3ø, 4 Wire (plus ground), wye
Output Frequency
60 Hz (± 0.1 Hz on battery)
Voltage Regulation
±2%
Max. Harmonic Distortion
(Non-Linear Full Load)
<5%
Overload Capabilities
102% (continuous), 102%~125% (1 min.),
125%~150% (30 sec.),
150% (2 sec.)
Short Circuit Capability
250A
Crest Factor
3:1
Battery
Battery Type
Sealed, Lead Acid, 240V DC, 9AH
Battery Pack Quantity
Five Packs (20 12V DC Batteries per pack)
Protection
Ten UL-recognized 30A 600VDC rated cartridge
fuses (two per battery pack) and fuse block
(1 per battery pack)
Typical Backup Time (Half Load)
25 min. +
Typical Backup Time (Full Load)
11 min. +
Operation
On-Line Transfer Time
(Line to Battery, Battery to Line)
0 ms
Audible Noise (Full Load @ 1 meter)
<65 dBA
Indicators
Includes an LCD Display and LEDs (AC Line In, Bypass Line In, AC to DC, DC to AC,
AC Output, Battery Back-Up, Bypass).
Communications
Includes an RS-232 DB9 female connector, an AS-400 DB9 female connector, a dry contact
DB9 female connector and an accessory slot.
Connections
Input Terminal Block
100A
Output Terminal Block
100A
Physical Specifications
Unit Dimensions (H x W x D)
48.5 x 19.3 x 36 in.
Unit Weight
935 lb.
Shipping Dimensions (H x W x D)
61.5 x 31 x 44.5
Shipping Weight
1152 lb.
9. Specifications
(
continued
)
1111 W. 35th Street, Chicago, IL
60609 USA
www.tripplite.com/support
+ Backup times are expandable with additional Battery Packs, sold separately. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.