Tripp Lite TLP82D Owner's Manual for 230V Surge 932848 - Page 2
Protect It!™, 230V Surge Suppressors
View all Tripp Lite TLP82D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
English Owner's Manual Protect It!™ 230V Surge Suppressors Copyright © 2008. All rights reserved. Protect It!™ Is a trademark of Tripp Lite. Tripp Lite World Headquarters 1111 W. 35th Street Chicago, IL 60609 +1.773.869.1234 • www.tripplite.com IMPORTANT SAFETY INFORMATION. SAVE THESE INSTRUCTIONS. Important Safety Warnings CAUTION! DO NOT connect to an ungrounded outlet. DO NOT use with 2-wire extension cords or adapters. This product is designed for indoor use only. Install the product away from heat-emitting appliances such as radiators or heat registers. Do not install where excessive moisture is present. Do not plug extension cords into it. Never install electrical, telephone, network or coaxial wiring during a lightning storm. Do not drill into any part of the housing or open the housing for any reason. There are no user-serviceable parts inside. WARNING! Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. Installation Mount Your Surge Suppressor (Optional Installation): If desired, mount your surge suppressor on a wall or other sturdy, vertical surface. However, you must mount the surge suppressor prior to connecting your equipment. Place a sheet of paper over the product's mounting holes and mark their centers with a push pin. Next, place this template over the desired area and mark with the push pins. Install screws (usersupplied) into the marks until 0.5 cm (¼ in.) of the screw heads are exposed. Mount the product over the screw heads and slide into place. Connect Your Surge Suppressor to the AC Power Line: Plug the product's power cord into a standard, 3-wire grounded 230V AC, 60 Hz outlet. Turn Your Surge Suppressor ON: Press the product's power switch to "ON". (Select models feature an illuminated switch.) Check Your Surge Suppressor's Diagnostic Indicator Light: If your surge suppressor features a diagnostic LED, check it prior to connecting your equipment. It will indicate operating conditions when the surge suppressor is plugged into a live 230V AC outlet and the surge suppressor's power switch is on. "PROTECTED" LED (Select Models Only): Indicates the surge suppression components are intact and providing complete protection against surges. If this LED does not illuminate, some of the surge suppression components are not functioning, and the unit should be replaced. "GROUNDED" LED (Select Models Only): Indicates wall outlet is grounded and surge protection can properly function. If this light DOES NOT illuminate and power is present, consult a qualified electrician to examine your outlet's wiring. "CONNECTED" LED (Select Models Only): If your surge suppressor includes Master/Subordinate Outlets (see "Master/Subordinate Outlets" section), this LED indicates a device is connected to the "Master" outlet and a peripheral device is connected to at least one of the "Subordinate" outlets and is functioning properly. Connect Your Equipment to the Surge Suppressor's AC Outlets: Plug your equipment's power cords (including 2-wire devices) into the product's AC outlets. All models feature safety outlets which automatically close when plug is removed. Select models also feature special widely-spaced outlets to accommodate transformers without covering other outlets. DO NOT plug in extension cords. DO NOT OVERLOAD the product's outlets. The product can accommodate a total equipment load of up to 10 amps (whether plugged into a single outlet or spread out over multiple outlets). If the load on the surge suppressor exceeds 10 amps, the circuit breaker* will trip and the outlets will stop providing power. If the circuit breaker trips, reduce the load by unplugging some devices. Depress the circuit breaker to reset. * Circuit breakers are integrated into the power switch on select models. Master/Subordinate Outlets (Select Models Only): This feature allows one main outlet to control up to three peripheral devices. The outlet that controls the peripheral devices is labeled "Master" and the three-outlet array for the peripheral devices is labeled "Connected by Master". For example, when a PC connected to the "Master" outlet is switched on or off, any device(s) connected to any of the "Subordinate" outlets (such as a monitor, printer, etc.) will simultaneously be switched on or off as well. Connect Your Equipment to the Surge Suppressor's Coaxial Jacks (Optional Installation. Select Models Only): Connect the included coaxial cable from the wall jack directly to the surge suppressor's gold-plated "F" style coaxial jack labeled "IN". Connect the coaxial cable from the surge suppressor's gold-plated "F" style coaxial jack labeled "OUT" directly to the device to be protected. (For aerial connections, select models also include one aerial cable and two aerial connectors.) The surge suppressor must always be the first item connected in line from the coaxial wall jack. The surge suppressor must be plugged into a 3-wire grounded AC outlet for coaxial line surge protection to work. Connect Your Equipment to the Surge Suppressor's Network Jacks* (Optional Installation. Select Models Only): Connect the included data cord from the wall jack or cable/DSL modem directly to the surge suppressor's network jack labeled "IN". Connect a data cord from the surge suppressor's network jack labeled "OUT" directly to the device to be protected (typically a computer's network interface card). The surge suppressor must always be the first item connected in line from the Ethernet source (typically a wall jack). The surge suppressor must be plugged into a 3-wire grounded AC outlet for network line surge protection to work. *10/100 BaseT/TX, Token Ring. Not compatible with PoE (Power Over Ethernet) applications. Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking name or model number of the product. Ex. 1234-ABC-198 WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union) is available at www.tripplite.com/environmental. For information on Tripp Lite's Ultimate Lifetime Protection Policy, visit www.tripplite.com. Tripp Lite follows a policy of continuous improvement. Product specifications are subject to change without notice. Actual product may differ slightly from carton photo. Made in China. English 200806196 93-2848