URC LT-3201-BR Owners Manual - Page 9

Association Groups

Page 9 highlights

LT-3200 Switch Association Groups Group 1: Lifeline Members of this group will receive unsolicited messages related to the status of the switch. Group 2: Basic Setup Sends start and stop level change to associated devices. Grouping Identifier Max Nodes Group 1 0x05 Group 2 0x05 Send Commands Central Scene Notification Basic Report Device Reset Locally Protection Report Basic Set Factory Default You may factory reset the switch by holding down the Config Button for twenty (20) or more seconds. The LED Bar will turn Red and blink three (3) times to confirm. However, we recommend using a certified Z-Wave controller to remove the device from your network for factory resetting the switch. Only use either of these procedures in the event that the network primary controller is missing or otherwise inoperable. Z-Wave Command Classes 5E - COMMAND_CLASS_ZWAVEPLUS_INFO 26 - COMMAND_CLASS_DIMMER_MULTILEVEL 70 - COMMAND_CLASS_CONFIGURATION 85 - COMMAND_CLASS_ASSOCIATION 59 - COMMAND_CLASS_ASSOCIATION_GRP_INFO 55 - COMMAND_CLASS_TRANSPORT_SERVICE 86 - COMMAND_CLASS_VERSION 72 - COMMAND_CLASS_MANUFACTURER_SPECIFIC 5A - COMMAND_CLASS_DEVICE_RESET_LOCALLY 73 - COMMAND_CLASS_POWERLEVEL 98 - COMMAND_CLASS_SECURITY 9F - COMMAND_CLASS_SECURITY_2 5B - COMMAND_CLASS_CENTRAL_SCENE 6C - COMMAND_CLASS_SUPERVISION 32 - COMMAND_CLASS_METER 75 - COMMAND_CLASS_PROTECTION 22 - COMMAND_CLASS_APPLICATION_STATUS 7A - COMMAND_CLASS_FIRMWARE_UPDATE_MD 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

LT-3200 Switch
9
Z-Wave Command Classes
5E-COMMAND_CLASS_ZWAVEPLUS_INFO
26-COMMAND_CLASS_DIMMER_MULTILEVEL
70-COMMAND_CLASS_CONFIGURATION
85-COMMAND_CLASS_ASSOCIATION
59-COMMAND_CLASS_ASSOCIATION_GRP_INFO
55 - COMMAND_CLASS_TRANSPORT_SERVICE
86 - COMMAND_CLASS_VERSION
72-COMMAND_CLASS_MANUFACTURER_SPECIFIC
5A-COMMAND_CLASS_DEVICE_RESET_LOCALLY
73-COMMAND_CLASS_POWERLEVEL
98-COMMAND_CLASS_SECURITY
9F-COMMAND_CLASS_SECURITY_2
5B-COMMAND_CLASS_CENTRAL_SCENE
6C-COMMAND_CLASS_SUPERVISION
32-COMMAND_CLASS_METER
75-COMMAND_CLASS_PROTECTION
22-COMMAND_CLASS_APPLICATION_STATUS
7A-COMMAND_CLASS_FIRMWARE_UPDATE_MD
Factory Default
YoumayfactoryresettheswitchbyholdingdowntheConfigButtonfortwenty(20)ormoreseconds.TheLED
BarwillturnRedandblinkthree(3)timestoconfirm.However,werecommendusingacertifiedZ-Wave
controllertoremovethedevicefromyournetworkforfactoryresettingtheswitch.Onlyuseeitherofthese
proceduresintheeventthatthenetworkprimarycontrollerismissingorotherwiseinoperable.
Association Groups
Group 1: Lifeline
Membersofthisgroupwillreceiveunsolicitedmessagesrelatedtothestatusoftheswitch.
Group 2: Basic Setup
Sends start and stop level change to associated devices.
Grouping Identifier
Max
Nodes
Send Commands
Group 1
0x05
Central Scene Notification
Basic Report
DeviceResetLocally
Protection Report
Group 2
0x05
BasicSet