Vantec MRK-M2508T Datasheet - Page 2

SATA/SAS Port Connectors D01 - D12

Page 2 highlights

L01 B01 L02 B02 P05 F02 SW1 B01 L01 B02 L02 L03 B03 L04 B04 L03 L04 D03 F01 D04 L05 L06 L07 L08 B03 B04 D01 D02 LED Indicators (L01-L04) BLUE - Power ON PURPLE - Disk performing reading/writing RED - On all 4 LEDs (L0l-L04), constant ashing indicate FAN Failure NO LED - No power to the drive bay, no drive in the tray LED Function Switch (SW1) Left Blue for Power LED No Disk Activity LED Red for Fan Failure LED Right Blue for Power LED Purple for Disk Activity LED Red for Fan Failure LED Power Connector (P05) Single Power connection for all 4 Bays SATA/SAS Port Connectors (D01 - D04) Data port (D01) - B01 Data port (D02) - B02 Data port (D03) - B03 Data port (D04) - B04 Note: 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller 2) SAS drive only support Primary Channel FANS (F01, F02) Both Fans pull air from the front of the Storage Bays. It uses two 40x40x20mm Fans. If any one of the Fans fails, the Four LED (L01- L04) will start blinking RED Over Heating If the Four LED (L01 - L04) start to blink RED very rapidly, the temperature in the Storage Bay have exceeded the safe temperature of 60 degree C. Signal Extension Connectors (HDD activity, Fan, Temperature) P01 B05 D05 B06 D06 P02 D01 D02 T +, TR - Temperature F+, FR - Fan Hdd+, l - HDD activity LED for B01 Hdd+, 2 - HDD activity LED for B02 Hdd+, 3 - HDD activity LED for B03 Hdd+, 4 - HDD activity LED for B04 Hdd+, 5 - HDD activity LED for B05 Hdd+, 6 - HDD activity LED for B06 Hdd+, 7 - HDD activity LED for B07 Hdd+, 8 - HDD activity LED for B08 SATA/SAS Port Connectors (D01 - D08) F01 B07 D07 SW1 Data port (D01) - B01 Data port (D05) - B05 D03 Data port (D02) - B02 Data port (D06) - B06 Data port (D03) - B03 Data port (D07) - B07 B08 D08 Data port (D04) - B04 Data port (D08) - B08 D04 Note: 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller 2) SAS drive only support Primary Channel HDD activity LED Switch(SW1) ON - Show Disk Activity (Orange LED) O - Show only Green Power LED (If Drive(s) is in the tray) Low - 2400 rpm High - 3000 rpm Fan Speed Switch Power Connector (P01,P02) Dual Power connection for all 8 Bays Note: -Both Power connectors must be connected from the system power supply -Power load balance by all attached drives FANS (F01) Fan pulls air from the front of the Storage Bays. Fan size: 70x70mm FAN Failure see F1 status LED Indicators (L01-L08) GREEN - Power ON ORANGE - Disk performing reading/writing NO LED - No power to the drive bay, no drive in the tray LED Temperature Status (T1) Normal - No LED Exceeded safe temp of 60 degrees C - Solid RED LED Fan Status (F1) Normal - No LED Fan Failure - Solid RED B01 L01 B02 L02 L03 B03 L04 B04 L05 B05 B06 L06 Signal Extension Connectors P01 P02 P03 (HDD activity, Fan, Temperature) HDD activity LED Switch(SW1) SATA/SAS Port Connectors (D01 - D12) L07 B07 D07 L08 B08 D08 T+, TR - Temperature F+, FR - Fan ON - Show Disk Activity (Orange LED) Data port (D01) - B01 Data port (D07) - B07 D01 Hdd+, l - HDD activity LED for B01 Hdd+, 2 - HDD activity LED for B02 O - Show only Green Power LED (If Drive(s) is in the tray) Data port (D02) - B02 Data port (D03) - B03 Data port (D08) - B08 Data port (D09) - B09 Hdd+, 3 - HDD activity LED for B03 Low - 2400 rpm Data port (D04) - B04 Data port (D10) - B10 Hdd+, 4 - HDD activity LED for B04 High - 3000 rpm Data port (D05) - B05 Data port (D11) - B11 D02 Hdd+, 5 - HDD activity LED for B05 Fan Speed Switch Data port (D06) - B06 Data port (D12) - B12 Hdd+, 6 - HDD activity LED for B06 Note: L09 B09 D09 F01 D03 Hdd+, 7 - HDD activity LED for B07 Hdd+, 8 - HDD activity LED for B08 Hdd+, 9 - HDD activity LED for B09 FANS (F01) Fan pulls air from the front of the Storage Bays. 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected L10 B10 Hdd+, 10 - HDD activity LED for B10 Hdd+, 11 - HDD activity LED for B11 Fan size: 80 x 80 x15mm FAN Failure see F1 status to SAS controller 2) SAS drive only support Primary Channel D10 D04 Hdd+, 12 - HDD activity LED for B12 L11 B11 D11 L12 B12 D12 Power Connector (P01,P02,P03 ) LED Indicators (L01-L12) LED Temperature Status (T1) D05 Three Power connection for all 12 Bays GREEN - Power ON Normal - No LED ORANGE - Disk performing reading/writing Exceeded safe temp of 60 degree C - Solid RED Note: NO LED - No power to the drive bay, no -Three Power connectors must be connected from the system power supply drive in the tray LED Fan Status (F1) D06 -Power load balance by all attached drives Normal - No LED Fan Failure - Solid RED SW1 W .PEFM.3,.5.3,.5.3,.5 XXXWBOUFDVTBDPN

  • 1
  • 2

v 1.01
www.vantecusa.com
Model: MRK-M2504T/MRK-M2508T/MRK-M2512T
L01
L02
L07
L08
B01
B02
B07
B08
L03
L04
L09
L10
B03
B04
B09
B10
L05
L06
L11
L12
B05
B06
B11
B12
D03
D04
D01
D02
D05
D06
D09
D10
D07
D08
D11
D12
P01
P02
P03
F01
SW1
L01
L02
L05
L06
B01
B02
B05
B06
L03
L04
L07
L08
B03
B04
B07
B08
D03
D04
D01
D02
D07
D08
D05
D06
P01
P02
F01
SW1
LED Indicators (L01-L04)
BLUE
- Power ON
PURPLE
- Disk performing reading/writing
RED
- On all 4 LEDs (L0l-L04), constant flashing indicate FAN Failure
NO LED
- No power to the drive bay, no drive in the tray
FANS (F01, F02)
Both Fans pull air from the front of the Storage Bays.
It uses two 40x40x20mm Fans.
If any one of the Fans fails, the Four LED (L01- L04) will start blinking RED
Over Heating
If the Four LED (L01 – L04) start to blink RED very rapidly, the temperature in
the Storage Bay have exceeded the safe temperature of 60 degree C.
Power Connector (P05)
Single Power connection for all 4 Bays
LED Function Switch (SW1)
Left
Blue for Power LED
No Disk Activity LED
Red for Fan Failure LED
Right
Blue for Power LED
Purple for Disk Activity LED
Red for Fan Failure LED
SATA/SAS Port Connectors (D01 - D04)
Data port (D01) - B01
Data port (D02) - B02
Data port (D03) - B03
Data port (D04) - B04
Note:
1)
You can mix SATA and SAS drives in the same storage unit, but SATA drives
HAVE to be connected to SATA controller and SAS drive HAVE to be connected
to SAS controller
2)
SAS drive only support Primary Channel
LED Indicators (L01-L08)
GREEN
- Power ON
ORANGE
- Disk performing reading/writing
NO LED
- No power to the drive bay, no
drive in the tray
LED Temperature Status (T1)
Normal
– No LED
Exceeded safe temp of 60 degrees C
– Solid RED
LED Fan Status (F1)
Normal
– No LED
Fan Failure
– Solid RED
FANS (F01)
Fan pulls air from the front of the Storage Bays.
Fan size: 70x70mm
FAN Failure see F1 status
SATA/SAS Port Connectors (D01 - D08)
Data port (D01) - B01
Data port (D02) - B02
Data port (D03) - B03
Data port (D04) - B04
Data port (D05) - B05
Data port (D06) - B06
Data port (D07) - B07
Data port (D08) - B08
Note:
1)
You can mix SATA and SAS drives in the same
storage unit, but SATA drives HAVE to be connected to
SATA controller and SAS drive HAVE to be connected
to SAS controller
2)
SAS drive only support Primary Channel
L01
D03
D04
SW1
D01
D02
L02
L03
L04
B01
B02
P05
F02
F01
B03
B04
Power Connector (P01,P02)
Dual Power connection for all 8 Bays
Note:
-Both Power connectors must be
connected from the system power supply
-Power load balance by all attached drives
T +, TR
- Temperature
F+, FR
- Fan
Hdd+,
l - HDD activity LED for B01
Hdd+, 2 - HDD activity LED for B02
Hdd+, 3 - HDD activity LED for B03
Hdd+, 4 - HDD activity LED for B04
Hdd+, 5 - HDD activity LED for B05
Hdd+, 6 - HDD activity LED for B06
Hdd+, 7 - HDD activity LED for B07
Hdd+, 8 - HDD activity LED for B08
Signal Extension Connectors
(HDD activity, Fan, Temperature)
HDD activity LED Switch(SW1)
ON
– Show Disk Activity (Orange LED)
Off
– Show only Green Power LED
(If Drive(s) is in the tray)
Fan Speed Switch
Low
– 2400 rpm
High
– 3000 rpm
LED Indicators (L01-L12)
GREEN
- Power ON
ORANGE
- Disk performing reading/writing
NO LED
- No power to the drive bay, no
drive in the tray
LED Temperature Status (T1)
Normal
– No LED
Exceeded safe temp of 60 degree C
– Solid RED
LED Fan Status (F1)
Normal
– No LED
Fan Failure
– Solid RED
FANS (F01)
Fan pulls air from the front of the Storage Bays.
Fan size: 80 x 80 x15mm
FAN Failure see F1 status
SATA/SAS Port Connectors (D01 - D12)
Data port (D01) - B01
Data port (D02) - B02
Data port (D03) - B03
Data port (D04) - B04
Data port (D05) - B05
Data port (D06) - B06
Data port (D07) - B07
Data port (D08) - B08
Data port (D09) - B09
Data port (D10) - B10
Data port (D11) - B11
Data port (D12) - B12
Note:
1)
You can mix SATA and SAS drives in the same
storage unit, but SATA drives HAVE to be connected to
SATA controller and SAS drive HAVE to be connected
to SAS controller
2)
SAS drive only support Primary Channel
Power Connector (P01,P02,P03
)
Three Power connection for all 12 Bays
Note:
-Three Power connectors must be
connected from the system power supply
-Power load balance by all attached drives
T+, TR
- Temperature
F+, FR
- Fan
Hdd+,
l
- HDD activity LED for B01
Hdd+, 2
- HDD activity LED for B02
Hdd+, 3
- HDD activity LED for B03
Hdd+, 4
- HDD activity LED for B04
Hdd+, 5
- HDD activity LED for B05
Hdd+, 6
- HDD activity LED for B06
Hdd+, 7
- HDD activity LED for B07
Hdd+, 8
- HDD activity LED for B08
Hdd+, 9
- HDD activity LED for B09
Hdd+, 10 - HDD activity LED for B10
Hdd+, 11 - HDD activity LED for B11
Hdd+, 12 - HDD activity LED for B12
Signal Extension Connectors
(HDD activity, Fan, Temperature)
HDD activity LED Switch(SW1)
ON
– Show Disk Activity (Orange LED)
Off
– Show only Green Power LED
(If Drive(s) is in the tray)
Fan Speed Switch
Low
– 2400 rpm
High
– 3000 rpm