Vantec MRK-M2508T Datasheet - Page 2
SATA/SAS Port Connectors D01 - D12
View all Vantec MRK-M2508T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
L01 B01 L02 B02 P05 F02 SW1 B01 L01 B02 L02 L03 B03 L04 B04 L03 L04 D03 F01 D04 L05 L06 L07 L08 B03 B04 D01 D02 LED Indicators (L01-L04) BLUE - Power ON PURPLE - Disk performing reading/writing RED - On all 4 LEDs (L0l-L04), constant ashing indicate FAN Failure NO LED - No power to the drive bay, no drive in the tray LED Function Switch (SW1) Left Blue for Power LED No Disk Activity LED Red for Fan Failure LED Right Blue for Power LED Purple for Disk Activity LED Red for Fan Failure LED Power Connector (P05) Single Power connection for all 4 Bays SATA/SAS Port Connectors (D01 - D04) Data port (D01) - B01 Data port (D02) - B02 Data port (D03) - B03 Data port (D04) - B04 Note: 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller 2) SAS drive only support Primary Channel FANS (F01, F02) Both Fans pull air from the front of the Storage Bays. It uses two 40x40x20mm Fans. If any one of the Fans fails, the Four LED (L01- L04) will start blinking RED Over Heating If the Four LED (L01 - L04) start to blink RED very rapidly, the temperature in the Storage Bay have exceeded the safe temperature of 60 degree C. Signal Extension Connectors (HDD activity, Fan, Temperature) P01 B05 D05 B06 D06 P02 D01 D02 T +, TR - Temperature F+, FR - Fan Hdd+, l - HDD activity LED for B01 Hdd+, 2 - HDD activity LED for B02 Hdd+, 3 - HDD activity LED for B03 Hdd+, 4 - HDD activity LED for B04 Hdd+, 5 - HDD activity LED for B05 Hdd+, 6 - HDD activity LED for B06 Hdd+, 7 - HDD activity LED for B07 Hdd+, 8 - HDD activity LED for B08 SATA/SAS Port Connectors (D01 - D08) F01 B07 D07 SW1 Data port (D01) - B01 Data port (D05) - B05 D03 Data port (D02) - B02 Data port (D06) - B06 Data port (D03) - B03 Data port (D07) - B07 B08 D08 Data port (D04) - B04 Data port (D08) - B08 D04 Note: 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller 2) SAS drive only support Primary Channel HDD activity LED Switch(SW1) ON - Show Disk Activity (Orange LED) O - Show only Green Power LED (If Drive(s) is in the tray) Low - 2400 rpm High - 3000 rpm Fan Speed Switch Power Connector (P01,P02) Dual Power connection for all 8 Bays Note: -Both Power connectors must be connected from the system power supply -Power load balance by all attached drives FANS (F01) Fan pulls air from the front of the Storage Bays. Fan size: 70x70mm FAN Failure see F1 status LED Indicators (L01-L08) GREEN - Power ON ORANGE - Disk performing reading/writing NO LED - No power to the drive bay, no drive in the tray LED Temperature Status (T1) Normal - No LED Exceeded safe temp of 60 degrees C - Solid RED LED Fan Status (F1) Normal - No LED Fan Failure - Solid RED B01 L01 B02 L02 L03 B03 L04 B04 L05 B05 B06 L06 Signal Extension Connectors P01 P02 P03 (HDD activity, Fan, Temperature) HDD activity LED Switch(SW1) SATA/SAS Port Connectors (D01 - D12) L07 B07 D07 L08 B08 D08 T+, TR - Temperature F+, FR - Fan ON - Show Disk Activity (Orange LED) Data port (D01) - B01 Data port (D07) - B07 D01 Hdd+, l - HDD activity LED for B01 Hdd+, 2 - HDD activity LED for B02 O - Show only Green Power LED (If Drive(s) is in the tray) Data port (D02) - B02 Data port (D03) - B03 Data port (D08) - B08 Data port (D09) - B09 Hdd+, 3 - HDD activity LED for B03 Low - 2400 rpm Data port (D04) - B04 Data port (D10) - B10 Hdd+, 4 - HDD activity LED for B04 High - 3000 rpm Data port (D05) - B05 Data port (D11) - B11 D02 Hdd+, 5 - HDD activity LED for B05 Fan Speed Switch Data port (D06) - B06 Data port (D12) - B12 Hdd+, 6 - HDD activity LED for B06 Note: L09 B09 D09 F01 D03 Hdd+, 7 - HDD activity LED for B07 Hdd+, 8 - HDD activity LED for B08 Hdd+, 9 - HDD activity LED for B09 FANS (F01) Fan pulls air from the front of the Storage Bays. 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected L10 B10 Hdd+, 10 - HDD activity LED for B10 Hdd+, 11 - HDD activity LED for B11 Fan size: 80 x 80 x15mm FAN Failure see F1 status to SAS controller 2) SAS drive only support Primary Channel D10 D04 Hdd+, 12 - HDD activity LED for B12 L11 B11 D11 L12 B12 D12 Power Connector (P01,P02,P03 ) LED Indicators (L01-L12) LED Temperature Status (T1) D05 Three Power connection for all 12 Bays GREEN - Power ON Normal - No LED ORANGE - Disk performing reading/writing Exceeded safe temp of 60 degree C - Solid RED Note: NO LED - No power to the drive bay, no -Three Power connectors must be connected from the system power supply drive in the tray LED Fan Status (F1) D06 -Power load balance by all attached drives Normal - No LED Fan Failure - Solid RED SW1 W .PEFM.3,.5.3,.5.3,.5 XXXWBOUFDVTBDPN