Vantec MRK-M3503T Datasheet - Page 2
Drive Bay - LED - DATA Connectors
View all Vantec MRK-M3503T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
B01 L01 P01 D01 SW1 T01 B03 F01 SW1 D03 P01 L03 SW2 B02 FAN1 D02 L02 P02 B01 D01 L01 T01 B04 F01 L04 B03 L03 B02 L02 B01 L01 T01 F01 B01 B02 B03 B04 B05 P01 P02 SW2 SW1 D04 D03 FAN1 D02 D01 D05 D04 D03 D02 D01 P01 P02 FAN1 L01 L02 L03 L04 L04 SW2 SW1 LED Indicators (L01) Power Connector (P01) GREEN - Power ON Power Connection for the single Bay GREEN with ORANGE Blink - Disk Activity RED - Drive Powered, but no data connection on Back No LED - No power to the Drive Bay, No drive in the Tray HDD Activity LED Switch (SW1) ON - Show Disk Activity OFF - Show Green Power LED (If Drive(s) is in the tray) Drive Bay - LED - DATA Connectors [Corresponding Drive Bay, LED and DATA Connectors (on Back)] Drive Bay 1(B01) - L01 - D01 Note: 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller SAS drive only support Primary Channel LED Indicators (L01-L03) GREEN - Power ON GREEN with ORANGE Blink - Disk Activity RED - Drive Powered, but no data connection on Back No LED - No power to the Drive Bay, No drive in the Tray LED Temperature (T01) Normal - Green LED Exceeding Set Temperature - Red LED Fan Speed Switch (SW1) LOW - 2400 rpm HIGH- 3000 rpm HDD Activity LED Switch (SW2) ON - Show Disk Activity OFF - Show Green Power LED (If Drive(s) is in the tray) Power Connector (P01, P02) Dual Power Connection for all 3 Bays Note: 1) Two Power Connectors must be connected from the system power supply 2) Power load balance by all attached drives FAN1 - Fan pull air from the front of the Storage Bays - Fan Size: 70 x 70 mm Fan - Fan Status (F01) - will show Red LED if fan Fails LED Fan Status (F01) Normal - Green LED Fan Failure - Red LED LED Indicators (L01-L04) GREEN - Power ON GREEN with ORANGE Blink - Disk Activity RED - Drive Powered, but no data connection on Back No LED - No power to the Drive Bay, No drive in the Tray LED Temperature (T01) Normal - Green LED Exceeding Set Temperature - Red LED Power Connector (P01, P02) Dual Power Connection for all 4 Bays Note: 1) Two Power Connectors must be connected from the system power supply 2) Power load balance by all attached drives Fan Speed Switch (SW1) LOW - 2400 rpm HIGH- 3000 rpm HDD Activity LED Switch (SW2) ON - Show Disk Activity OFF - Show Green Power LED (If Drive(s) is in the tray) FAN1 - Fan pull air from the front of the Storage Bays - Fan Size: 80 x 80 mm Fan - Fan Status (F01) - will show Red LED if fan Fails LED Fan Status (F01) Normal - Green LED Fan Failure - Red LED Default Internal Storage Unit Temperature set to 60°C, you can change the jumper to either 55°C, 60° C or 65°C Fan Status LED, Set via FR, F+, FG Temperature Status LED, set via TR, T+, TG Hard Drive Activity LED set via +HDD, 3; +HDD, 2; +HDD, 1 Drive Bay - LED - DATA Connectors [Corresponding Drive Bay, LED and DATA Connectors (on Back)] Drive Bay 1(B01) - L01 - D01 Drive Bay 2(B02) - L02 - D02 Drive Bay 3(B03) - L03 - D03 Note: 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller 2) SAS drive only support Primary Channel Default Internal Storage Unit Temperature set to 60°C, you can change the jumper to either 55°C, 60°C or 65°C Fan Status LED, Set via FR, F+, FG Temperature Status LED, set via TR, T+, TG Hard Drive Activity LED set via +HDD, 4;+HDD, 3; +HDD, 2; +HDD, 1 Drive Bay - LED - DATA Connectors [Corresponding Drive Bay, LED and DATA Connectors (on Back)] Drive Bay 1(B01) - L01 - D01 Drive Bay 2(B02) - L02 - D02 Drive Bay 3(B03) - L03 - D03 Drive Bay 4(B04) - L04 - D04 Note: 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller 2) SAS drive only support Primary Channel LED Indicators (L01-L05) GREEN - Power ON GREEN with ORANGE Blink - Disk Activity RED - Drive Powered, but no data connection on Back No LED - No power to the Drive Bay, No drive in the Tray LED Temperature (T01) Normal - Green LED Exceeding Set Temperature - Red LED Fan Speed Switch (SW1) LOW - 2400 rpm HIGH- 3000 rpm HDD Activity LED Switch (SW2) ON - Show Disk Activity OFF - Show Green Power LED (If Drive(s) is in the tray) Power Connector (P01, P02) Dual Power Connection for all 5 Bays Note: 1) Two Power Connectors must be connected from the system power supply 2) Power load balance by all attached drives FAN1 - Fan pull air from the front of the Storage Bays - Fan Size: 80 x 80 mm Fan - Fan Status (F01) - will show Red LED if fan Fails LED Fan Status (F01) Normal - Green LED Fan Failure - Red LED Default Internal Storage Unit Temperature set to 60°C, you can change the jumper to either 55°C, 60°C or 65°C Fan Status LED, Set via FR, F+, FG Temperature Status LED, set via TR, T+, TG Hard Drive Activity LED set via +HDD, 1;+HDD, 2;+HDD, 3; +HDD, 4; +HDD, 5 Drive Bay - LED - DATA Connectors [Corresponding Drive Bay, LED and DATA Connectors (on Back)] Drive Bay 1(B01) - L01 - D01 Drive Bay 2(B02) - L02 - D02 Drive Bay 3(B03) - L03 - D03 Drive Bay 4(B04) - L04 - D04 Drive Bay 5(B05) - L05 - D05 Note: 1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller 2) SAS drive only support Primary Channel W .PEFM.3,.5.3,.5.3,.5.3,.5 XXXWBOUFDVTBDPN