RS-232C Communication (continued) Names Operation Type Header CRC Command Data Action Type Setting Code Power Input Source Error Status Set Turn off BE EF 03 06 00 2A D3 01 00 00 60 00 00 Turn on BE EF 03 06 00 BA D2 01 00 00 60 01 00 Get BE EF 03 06 00 19 D3 02 00 00 60 00 00 [Example return] 00 00 [Off] 01 00 [On] 02 00 [Cool down] Set COMPUTER 1 BE EF 03 06 00 FE D2 01 00 00 20 00 00 COMPUTER 2 BE EF 03 06 00 3E D0 01 00 00 20 04 00 VIDEO BE EF 03 06 00 6E D3 01 00 00 20 01 00 S-VIDEO BE EF 03 06 00 9E D3 01 00 00 20 02 00 Get BE EF 03 06 00 CD D2 02 00 00 20 00 00 Get BE EF 03 06 00 D9 D8 02 00 20 60 00 00 [Example return] 00 00 01 00 02 00 03 00 [Normal] [Cover error] [Fan error] [Lamp error] 04 00 05 00 06 00 07 00 [Temp error] [Air flow error] [Lamp time error] [Cool error] 08 00 09 00 10 00 [Filter error] (Filter missing error)(Inner Sencer error) BRIGHTNESS Get BE EF 03 06 00 89 D2 02 00 Increment BE EF 03 06 00 EF D2 04 00 Decrement BE EF 03 06 00 3E D3 05 00 BRIGHTNESS Reset Execute BE EF 03 06 00 58 D3 06 00 CONTRAST Get BE EF 03 06 00 FD D3 02 00 Increment BE EF 03 06 00 9B D3 04 00 Decrement BE EF 03 06 00 4A D2 05 00 CONTRAST Reset Execute BE EF 03 06 00 A4 D2 06 00 PICTURE MODE Set NORMAL BE EF 03 06 00 23 F6 01 00 CINEMA BE EF 03 06 00 B3 F7 01 00 DYNAMIC BE EF 03 06 00 E3 F4 01 00 BOARD(BLACK) BE EF 03 06 00 E3 EF 01 00 DAYLIGHT MODE BE EF 03 06 00 23 E2 01 00 WHITEBOARD BE EF 03 06 00 83 EE 01 00 Get BE EF 03 06 00 10 F6 02 00 [Example return] 00 00 01 00 04 00 10 00 [Normal] [Cinema] [Dynamic] [Custom] 20 00 30 00 [BOARD(BLACK) ] [DAYLIGHT MODE] GAMMA Set #1 DEFAULT BE EF 03 06 00 07 E9 01 00 #1 CUSTOM BE EF 03 06 00 07 FD 01 00 #2 DEFAULT BE EF 03 06 00 97 E8 01 00 #2 CUSTOM BE EF 03 06 00 97 FC 01 00 #3 DEFAULT BE EF 03 06 00 67 E8 01 00 #3 CUSTOM BE EF 03 06 00 67 FC 01 00 #4 DEFAULT BE EF 03 06 00 F7 E9 01 00 #4 CUSTOM BE EF 03 06 00 F7 FD 01 00 #5 DEFAULT BE EF 03 06 00 C7 EB 01 00 #5 CUSTOM BE EF 03 06 00 C7 FF 01 00 Get BE EF 03 06 00 F4 F0 02 00 03 20 03 20 03 20 00 70 04 20 04 20 04 20 01 70 BA 30 BA 30 BA 30 BA 30 BA 30 BA 30 BA 30 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 04 00 20 00 30 00 22 00 00 00 22 00 [WHITEBOARD] A1 30 20 00 A1 30 10 00 A1 30 21 00 A1 30 11 00 A1 30 22 00 A1 30 12 00 A1 30 23 00 A1 30 13 00 A1 30 24 00 A1 30 14 00 A1 30 00 00 ViewSonic 60 PJL3211

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

60
ViewSonic
PJL3211
Names
Operat±on Type
Header
Command Data
CRC
Act±on
Type
Sett±ng Code
Power
Set
Turn off
BE
EF
03
06
00
2A
D3
01
00
00
60
00
00
Turn on
BE
EF
03
06
00
BA
D2
01
00
00
60
01
00
Get
BE
EF
03
06
00
19
D3
02
00
00
60
00
00
[Example return]
00
00
01
00
02
00
[Off]
[On]
[Cool down]
Input Source
Set
COMPUTER 1
BE
EF
03
06
00
FE
D2
01
00
00
20
00
00
COMPUTER 2
BE
EF
03
06
00
3E
D0
01
00
00
20
04
00
VIDEO
BE
EF
03
06
00
6E
D3
01
00
00
20
01
00
S-VIDEO
BE
EF
03
06
00
9E
D3
01
00
00
20
02
00
Get
BE
EF
03
06
00
CD
D2
02
00
00
20
00
00
Error Status
Get
BE
EF
03
06
00
D9
D8
02
00
20
60
00
00
[Example return]
00
00
01
00
02
00
03
00
[Normal]
[Cover error]
[Fan error]
[Lamp error]
04
00
05
00
06
00
07
00
[Temp error]
[Air flow error] [Lamp time error]
[Cool error]
08 00
09 00
10 00
[F±lter error]
(F±lter m±ss±ng error)(Inner Sencer error)
BRIGHTNESS
Get
BE
EF
03
06
00
89
D2
02
00
03
20
00
00
Increment
BE
EF
03
06
00
EF
D2
04
00
03
20
00
00
Decrement
BE
EF
03
06
00
3E
D3
05
00
03
20
00
00
BRIGHTNESS
Reset
Execute
BE
EF
03
06
00
58
D3
06
00
00
70
00
00
CONTRAST
Get
BE
EF
03
06
00
FD
D3
02
00
04
20
00
00
Increment
BE
EF
03
06
00
9B
D3
04
00
04
20
00
00
Decrement
BE
EF
03
06
00
4A
D2
05
00
04
20
00
00
CONTRAST Reset
Execute
BE
EF
03
06
00
A4
D2
06
00
01
70
00
00
PICTURE MODE
Set
NORMAL
BE
EF
03
06
00
23
F6
01
00
BA
30
00
00
CINEMA
BE
EF
03
06
00
B3
F7
01
00
BA
30
01
00
DYNAMIC
BE
EF
03
06
00
E3
F4
01
00
BA
30
04
00
BOARD(BLACK)
BE
EF
03
06
00
E3
EF
01
00
BA
30
20
00
DAYLIGHT MODE
BE
EF
03
06
00
23
E2
01
00
BA
30
30
00
WHITEBOARD
BE
EF
03
06
00
83
EE
01
00
BA
30
22
00
Get
BE
EF
03
06
00
10
F6
02
00
BA
30
00
00
[Example return]
00
00
01
00
04
00
10
00
[Normal] [C±nema] [Dynam±c] [Custom]
20
00
30
00
22
00
[BOARD(BLACK) ]
[DAYLIGHT MODE]
[WHITEBOARD]
GAMMA
Set
#1 DEFAULT
BE
EF
03
06
00
07 E9
01
00
A1
30
20 00
#1 CUSTOM
BE
EF
03
06
00
07 FD
01
00
A1
30
10
00
#2 DEFAULT
BE
EF
03
06
00
97 E8
01
00
A1
30
21
00
#2 CUSTOM
BE
EF
03
06
00
97 FC
01
00
A1
30
11
00
#3 DEFAULT
BE
EF
03
06
00
67 E8
01
00
A1
30
22
00
#3 CUSTOM
BE
EF
03
06
00
67 FC
01
00
A1
30
12
00
#4 DEFAULT
BE
EF
03
06
00
F7 E9
01 00
A1 30
23 00
#4 CUSTOM
BE
EF
03
06
00
F7 FD
01 00
A1 30
13 00
#5 DEFAULT
BE
EF
03
06
00
C7 EB
01 00
A1 30
24 00
#5 CUSTOM
BE
EF
03
06
00
C7 FF
01 00
A1 30
14 00
Get
BE
EF
03
06 00
F4 F0
02
00
A1
30
00
00
RS-232C Communication (continued)