Viking 24" Custom Panel Fully Integrated All Refrigerator Installation Instruc - Page 21

Water Filter System Specification and Performance Data Sheet

Page 21 highlights

Water Filter System Specification and Performance Data Sheet This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration of less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety factors built-in for unmetered usage for health claims only.) Contaminant Reduction Chlorine Taste and Odor Nominal Particulate Class I, >0.5 to < 1.0 μm Asbestos Atrazine Cyst* Lead @ pH 6.5 Lead @ pH 8.5 Lindane Mercury @ pH 6.5 Mercury @ pH 8.5 Toxaphene Turbidity Average Influent 2.0 mg/L NSF Specified Challenge Concentration Avg % Reduction 2.0 mg/L + 10% 97.5% Average Product Water Concentration 0.05 mg/L Max Permissible Product Water Concentration NSF Reduction Requirements N/A > 50% NSF Test Report J-00056501 13,666,667 pts/mL At least 10,000 particles/mL 96 MF/L 0.010 mg/L 122,500 cysts/L 0.153 mg/L 0.150 mg/L 0.002 mg/L 0.006 mg/L 0.006 mg/L 0.015 mg/L 10.8 NTU 107 to 108 fibers/L; fibers greater than 10μm in length 0.009 mg/L + 10% Minimum 50,000 cysts/L 0.15 mg/L + 10% 0.15 mg/L + 10% 0.002 mg/L + 10% 0.006 mg/L + 10% 0.006 mg/L + 10% 0.015 mg/L + 10% 11 + 1 NTU 98.9% >99% 89.3% 99.99% 99.3% 99.3% 97.8% 95.0% 88% 93.2% 98.7% 143,333 pts/mL 85% J-00056506 > 99% J-00056511 N/A > 99.95% N/A N/A N/A N/A N/A N/A N/A J-00056512 J-00056513 J-00056515 J-00058784 J-00058969 J-00058785 J-00058783 J-00056531 J-00058972 *Based on the use of Cryptosporidium parvum oocysts Operating Specifications Capacity: Certified for up to 750 gallons (2,838 L); up to nine months Pressure Requirement: 20 - 120 psi (1.4 - 8.2 bar) Temperature: 33-100º F (0.6 - 37.8º C) Flow rate: 0.78 gpm (2.9 l/min.) Check for compliance with the state and local laws and regulations. Note: While the testing was performed under standard laboratory conditions, actual performance may vary. Must be installed and operated in accordance with manufacturer's recommended procedures and guidelines. Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. This drinking water system must be maintained according to manufacturer's instruction, including replacement of filter cartridges. Manufactured by: 3M Purification Inc. 400 Research Parkway Meriden, CT 06770 System tested and certified by NSF International against Standard 42 for the reduction of chlorine taste and odor, particulate Class I and Standard 53 for the reduction of Lead, Lindane, Atrazine, Mercury, Toxaphene, Cyst, Turbidity, and Asbestos. 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

21
Water Filter System Specification and Performance Data Sheet
Contaminant
Reduction
Average
Influent
NSF Specified Chal-
lenge
Concentration
Avg %
Reduction
Average
Product Water
Concentration
Max Permissible
Product Water
Concentration
NSF
Reduction
Requirements
NSF Test
Report
Chlorine Taste and
Odor
2.0 mg/L
2.0 mg/L + 10%
97.5%
0.05 mg/L
N/A
> 50%
J-00056501
Nominal Particulate
Class I, >0.5 to <
1.0 μm
13,666,667
pts/mL
At least 10,000
particles/mL
98.9%
143,333
pts/mL
N/A
> 85%
J-00056506
Asbestos
96 MF/L
10
7
to 10
8
fibers/L;
fibers greater than
10μm in length
>99%
<1 MF/L
N/A
> 99%
J-00056511
Atrazine
0.010 mg/L
0.009 mg/L + 10%
89.3%
0.001 mg/L
0.003 mg/L
N/A
J-00056512
Cyst*
122,500
cysts/L
Minimum 50,000
cysts/L
99.99%
1 cyst/L
N/A
> 99.95%
J-00056513
Lead @ pH 6.5
0.153 mg/L
0.15 mg/L + 10%
99.3%
0.001 mg/L
0.010 mg/L
N/A
J-00056515
Lead @ pH 8.5
0.150 mg/L
0.15 mg/L + 10%
99.3%
0.001 mg/L
0.010 mg/L
N/A
J-00058784
Lindane
0.002 mg/L
0.002 mg/L + 10%
97.8%
0.00004 mg/L
0.0002 mg/L
N/A
J-00058969
Mercury @ pH 6.5
0.006 mg/L
0.006 mg/L + 10%
95.0%
0.0003 mg/L
0.002 mg/L
N/A
J-00058785
Mercury @ pH 8.5
0.006 mg/L
0.006 mg/L + 10%
88%
0.0007 mg/L
0.002 mg/L
N/A
J-00058783
Toxaphene
0.015 mg/L
0.015 mg/L + 10%
93.2%
0.001 mg/L
0.003 mg/L
N/A
J-00056531
Turbidity
10.8 NTU
11 + 1 NTU
98.7%
0.153 NTU
0.5 NTU
N/A
J-00058972
*Based on the use of Cryptosporidium parvum oocysts
Operating Specifications
Capacity:
Certified for up to 750 gallons (2,838 L); up to nine months
Pressure Requirement:
20 - 120 psi (1.4 - 8.2 bar)
Temperature:
33-100º F (0.6 - 37.8º C)
Flow rate:
0.78 gpm (2.9 l/min.)
Check for compliance with the state and local laws and regulations.
Note:
While the testing was performed under standard laboratory conditions, actual performance may vary.
Must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines. Installation instructions, parts
and service availability, and standard warranty are included with the product when shipped. This drinking water system must be maintained
according to manufacturer’s instruction, including replacement of filter cartridges.
Manufactured by:
3M Purification Inc.
400 Research Parkway
Meriden, CT
06770
System tested and certified by NSF International against
Standard 42 for the reduction of chlorine taste and odor,
particulate Class I and Standard 53 for the reduction
of Lead, Lindane, Atrazine, Mercury, Toxaphene, Cyst,
Turbidity, and Asbestos.
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration of less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI 42/53.* (100% safety factors built-in for unmetered usage for health claims only.)