Viking DCCG1304BSS Specs - Page 4

COOKING, Installation Requirements - propane

Page 4 highlights

COOKING Designer Freestanding Gas 30"W. Sealed Burner Range UTILITY REQUIREMENTS GAS • Shipped natural gas standard; field convert to LP/propane with optional accessory kit or order as LP by adding LP after color code • Accepts standard residential 1/2" ID gas service line • Gas manifold pressure o Natural gas 5.0" W.C.P. o LP/Propane 10.0" W.C.P. ELECTRICAL • Four-foot (121.9 cm) cord included with range • Three-wire with ground/threeprong plug • 120 V/60 Hz • Maximum amp usage- o 30"W. 4B-.74 PLUMBING Not applicable Installation Requirements ACCESS REQUIREMENTS DCCG130-4B 30"W. Four Burner Range 3-1/8" (7.9 cm) 2" dia. (5.1 cm) Gas connection in this area 2-1/2" (6.4 cm) 1-7/8" (4.8 cm) 24-7/8" (63.2 cm) 32" (81.3 cm) 29-1/4" (79.3 cm) 3-1/2" (8.9 cm) Gas or electrical connection in this area Note: Ground plug and electrical wire toward the direction of the electrical outlet. Surface burner rating Left front Left rear Center Right rear Right front DCCG130-4B 16,000 BTU Nat. (4.7 kW)/15,500 BTU LP (4.5 kW) 12,000 BTU Nat. (3.5 kW)/11,500 BTU LP (3.4 kW) 8,000 BTU Nat. (2.0 kW)/7,500 BTU LP (1.9 kW) 6,000 BTU Nat. (1.5 kW)/5,500 BTU LP (1.4 kW) ** Top of grates should be 3/8" (1.0 cm) above countertop. Broil burner rating Bake burner rating 18,000 BTU Nat. (5.3 kW)/16,000 BTU LP (4.7 kW) 30,000 BTU Nat./LP (8.8 kW) PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 8/26/10 ©2010 VRC-INFORMATION SUBJECT TO CHANGE

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2”
dia.
(5.1 cm)
3-1/8”
(7.9 cm)
2-1/2”
(6.4 cm)
1-7/8”
(4.8 cm)
29-1/4”
(79.3 cm)
24-7/8”
(63.2 cm)
Gas or electrical
connection in
this area
Gas connection
in this area
3-1/2”
(8.9 cm)
32”
(81.3 cm)
COOKING
Designer Freestanding Gas 30”W. Sealed Burner Range
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM
1-888-VIKING1
REVISED 8/26/10
©2010 VRC—INFORMATION SUBJECT TO CHANGE
UTILITY
REQUIREMENTS
GAS
• Shipped natural
gas standard;
field convert to
LP/propane with
optional accessory
kit or order as LP
by adding LP
after color code
• Accepts standard
residential 1/2” ID
gas service line
• Gas manifold
pressure
o Natural gas 5.0”
W.C.P.
o LP/Propane
10.0” W.C.P.
ELECTRICAL
• Four-foot (121.9
cm) cord included
with range
• Three-wire with
ground/three-
prong plug
• 120 V/60 Hz
• Maximum amp
usage—
o
30”W. 4B—.74
PLUMBING
Not applicable
Installation Requirements
ACCESS REQUIREMENTS
Note:
Ground plug and electrical wire toward the direction of the electrical outlet.
DCCG130-4B
Surface burner rating
Left front
16,000 BTU Nat. (4.7 kW)/15,500 BTU LP (4.5 kW)
Left rear
12,000 BTU Nat. (3.5 kW)/11,500 BTU LP (3.4 kW)
Center
Right rear
8,000 BTU Nat. (2.0 kW)/7,500 BTU LP (1.9 kW)
Right front
6,000 BTU Nat. (1.5 kW)/5,500 BTU LP (1.4 kW)
** Top of grates should be 3/8” (1.0 cm) above countertop.
Broil burner rating
18,000 BTU Nat. (5.3 kW)/16,000 BTU LP (4.7 kW)
Bake burner rating
30,000 BTU Nat./LP (8.8 kW)
DCCG130-4B
30”W. Four Burner Range