Viking DDOE305SS Installation Instructions - Page 6

General Information, Electrical Requirements - direct

Page 6 highlights

Electrical Requirements • Oven requires a separate, grounded 4-wire, 240V (AC), 30 amp (single ovens) and 50 amp (double ovens) service with its own circuit breaker. • Wire sizes and connections must conform with the rating of the appliance and to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, or Canadian Electrical Code, CSA C22.1-1982 and C22.2 No. 01982 - latest edition, and all local codes and ordinances. • Oven must be connected to the proper electrical voltage and frequency as specified on the model/serial rating plate (located inside the vent ont the right sode of the oven). • Oven must be connected to grounded metal permanent wiring system. Check with a qualified electrician to make sure the oven is properly grounded. • DO NOT ground to a gas pipe. • DO NOT use an extension cord with this appliance, because this may result in electrical shock or other personal injury. • This unit is equipped with a No. 10 ground wire in the conduit. • The electrical conduit must be kept to the top left for a flush installation. NEVER cut the conduit. • Connect the flexible armored cable directly to 4-wire, 240V household service. If codes permit and separate grounding wiring is used, we recommend that a qualified electrician determine the grounding path and that the wire gauge is in accordance with local codes. • Junction boxes installed on rear wall directly behind oven must be recessed . • A UL-Listed conduit connector must be provided at the junction box. • DO NOT install a fuse in the neutral or grounding circuit. We recommend a timedelayed fuse or circuit breaker. Connect directly to the fused disconnect (or circuit breaker box) through flexible armored, or non-metallic sheathed, copper cable (with grounding wire). 10 General Information • All openings in the wall behind the appliance or in the floor under the appliance should be sealed. • Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors. • Disconnect the electrical supply prior to servicing or cleaning. • When removing the appliance for cleaning or service, disconnect AC power supply and carefully remove the appliance by pulling forward. • Electrical requirements are listed in the product specifications under the electrical requirements section. Recommendations for Unpacking • Products are shipped on pallets with foam footings and corrugated inner-packing and exterior hoods. • Products are anchored to the pallet using metal straps that are screwed to the bottom of the product and the pallet. • DO NOT remove protective packaging until you are ready to perform the installation. • To remove the packaging, first remove the staples located at the bottom perimeter of the corrugated cover. • Remove the corrugated cover by lifting it off the product and remove the innerpacking. • Detach the product from the metal anchor strip by removing the attachment screw. • DO NOT remove the protective wrapping from the product control panel until the product is installed. Recommendations for Moving CAUTION The oven is heavy-use extreme care when handling. WARNING DO NOT use the handle or oven door to lift the oven. Remove door before installation to ensure that it is not used to lift the unit. DO NOT lift or carry the door by the handle. • Only proper equipment should be used to move products. • ALWAYS take steps to protect flooring at the installation location when moving products. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

General Information
• All openings in the wall behind the
appliance or in the floor under the
appliance should be sealed.
• Keep appliance area clear and free from
combustible materials, gasoline and other
flammable vapors.
• Disconnect the electrical supply prior to
servicing or cleaning.
• When removing the appliance for cleaning
or service, disconnect AC power supply
and carefully remove the appliance by
pulling forward.
• Electrical requirements are listed in the
product specifications under the electrical
requirements section.
Recommendations for Unpacking
• Products are shipped on pallets with foam
footings and corrugated inner-packing
and exterior hoods.
• Products are anchored to the pallet using
metal straps that are screwed to the
bottom of the product and the pallet.
DO NOT
remove protective packaging
until you are ready to perform the
installation.
• To remove the packaging, first remove the
staples located at the bottom perimeter
of the corrugated cover.
• Remove the corrugated cover by lifting
it off the product and remove the inner-
packing.
• Detach the product from the metal anchor
strip by removing the attachment screw.
DO NOT
remove the protective wrapping
from the product control panel until the
product is installed.
Recommendations for Moving
• Only proper equipment should be used to
move products.
ALWAYS
take steps to protect flooring at
the installation location when moving
products.
11
WARNING
DO NOT
use the handle or oven door
to lift the oven. Remove door before
installation to ensure that it is not used to
lift the unit.
DO NOT
lift or carry the door
by the handle.
CAUTION
The oven is heavy—use extreme care
when handling.
Electrical Requirements
• Oven requires a separate, grounded
4-wire, 240V (AC), 30 amp (single ovens)
and 50 amp (double ovens) service with
its own circuit breaker.
• Wire sizes and connections must conform
with the rating of the appliance and to the
requirements of the National Electrical
Code, ANSI/NFPA 70 – latest edition, or
Canadian Electrical Code, CSA
C22.1-1982 and C22.2 No. 01982 –
latest edition, and all local codes and
ordinances.
• Oven must be connected to the proper
electrical voltage and frequency as
specified on the model/serial rating plate
(located inside the vent ont the right sode
of the oven).
• Oven must be connected to grounded
metal permanent wiring system. Check
with a qualified electrician to make sure
the oven is properly grounded.
DO NOT
ground to a gas pipe.
DO NOT
use an extension cord with this
appliance, because this may result in
electrical shock or other personal injury.
• This unit is equipped with a No. 10
ground wire in the conduit.
• The electrical conduit must be kept to the
top left for a flush installation.
NEVER
cut
the conduit.
• Connect the flexible armored cable
directly to 4-wire, 240V household service.
If codes permit and separate grounding
wiring is used, we recommend that a
qualified electrician determine the
grounding path and that the wire gauge is
in accordance with local codes.
• Junction boxes installed on rear wall
directly behind oven must be recessed .
• A UL-Listed conduit connector must be
provided at the junction box.
DO NOT
install a fuse in the neutral or
grounding circuit. We recommend a time-
delayed fuse or circuit breaker. Connect
directly to the fused disconnect (or circuit
breaker box) through flexible armored, or
non-metallic sheathed, copper cable (with
grounding wire).
10