Viking DMOS201SS Installation Instructions - Page 4
General Information - designer series
View all Viking DMOS201SS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
General Information Par ts Included in the Kit 1) Frame Assembly: QTY 1 Cabinet or Wall Cutout 2) Bottom Duct Assembly: QTY 1 Item Part Name Frame Assembly Bottom Duct QTY 1 1 Cutout Dimensions Height Minimum Flush Mount 17-5/16" (439.8mm) Surface Mount 16-9/16" (420.7mm) Mounting Bracket 2 Screw A :1-3/16" length 2 Screw B: 1-3/4" length 4 Side Decoration (Surface Mount Only) 2 Surface Mounting Template 1 Width Maximum Minimum Maximum N/A 29-5/8" (752.5mm) N/A 16-13/16" (427mm) 27-3/4" (704.9mm) 28" (711.2mm) 1F) Flruasmhe AMssoemunbltyi:nQgTYT1emplate 3) Mouting 1 Bracket: Q2)TBYo2ttom DucDt eApsstehmb!ly: QTY M1 inimum4()SSUIRDFEADC2(EE5C0M0O"O3RmUANTmITOINN) G: QOTNYL2(2Y50)0"3mm) 2) Bottom Duct Assembly: QTY 1 4"(10.2 cm) 6"(15.2 cm) figure 1 2) Bottom Duct Assembly: QTY 1 4"(10.2 cm) 3) Mouting Bracket: QTY 2 4) SIDE DECORATION: QTY 2 (SURFACE MOUNTING ONLY) 4) SIDE DECORATION: QTY 2 (SURFACE MOUNTING ONLY) 2 4) SIDE DECOR ATION: QTY 2 (SURFACE MOUNTING ONLY) Maximum Cutout Opening Width 28" (711.2 mm) Minimum Cutout Opening Width 27-3/4" (704.9 mm) Electrical Outlet Location CAUTION Outlet should NOT be in the shaded area as indicated on figure . Minimum Cutout Opening Height 16-9/16" (420.7 mm) Maximum Cutout Opening Height 16-13/16" (427 mm) Distance between holes 9.1" (231.2 mm) BUILT-IN TRIM KIT SURFACE MOUNTING TEMPLATE FOR DESIGNER SERIES MICROWAVE OVEN Center Line 1. Align the Surface Mounting Template center line with the center of the cabinet. Align the Floor Line with the bottom of the cabinet at the desired height. Tape it into place. 2. Predrill 4 holes marked with a 5RQE" drill bit. 3. Cut the cabinet opening between the minimum and maximum cutout opening lines. Be careful to cut precisely along the Floor Line of the cutout. 4. Remove template from the cabinet. 14-1/4" (361.95 mm) 14" (355.6 mm) Floor Line of Cutout Opening Cutout Opening Width 29-5/8" (752.5 mm) CABINET CUTOUT LINE CABINET CUTOUT LINE CABINET CUTOUT LINE Distance between holes 9.1" (231.2 mm) Cutout Opening Height 17-5/16" (439.8 mm) SIDE SPACER TEMPLATE - R SIDE SPACER TEMPLATE - L FIGURE 1 FIGURE 2 FIGURE 3 14" (355.9 mm) 14-13/16" (376.2 mm) FLOOR LINE OF CUTOUT OPENING CENTER LINE BUILT-IN TRIM KIT FLUSH MOUNTING TEMPLATE FOR DESIGNER SERIES MICROWAVE OVEN 4-3/16" (106.4 mm) 3-15/16" (100 mm) NOTES: UÊ If the Depth (C) dimension is greater than 21" (53.3 cm), the outlet location may be in any area on the rear wall. UÊ The floor of the opening should be constructed of plywood strong enough to support the weight of the oven and floor load (approximately 100 pounds). The floor should be level for proper operation of the oven. Be sure to check the local building code as it may require that the opening be enclosed with side, ceiling and rear partition. The proper functioning of the oven does not require the enclosure. E 4