VENTILATION, Installation Requirements - direct
View all Viking DTWN4848SS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Installation Requirements VENTILATION Designer Built-In Wall Hoods DTWS Slim Traditional Wall Hood DTWN Tall Traditional Ledgeless Wall Hood UTILITY REQUIREMENTS Proper installation/ducting is extremely important to ensure maximum performance. Use a qualified and trained installer. DUCTING • Check with a qualified and trained installer or local codes for makeup air requirements, if any. • Max. duct run length o For 300 - 1,200 CFM-50' (152.4 m) o For 1,500 CFM-75' (22.9 m) o For general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer. o Straight runs and gradual turns are best; for example, each 90° elbow is equivalent to 5' - 10' (1.52 - 3.05 cm) of straight run. • 7" (17.8 cm) round duct for 300 - 600 CFM; 10" for 900 - 1500 CFM o Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance. GAS Not applicable ELECTRICAL • Hardwire direct with two-wire ground • 120 VAC/60 Hz • Max. amp usage (rating includes recommended ventilator kit rating)-see Dimensions & Specifications table PLUMBING Not applicable Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly overstated. Model DTWS3049 DTWS3649 DTWS4249 DTWS4849 DTWN3048 DTWN3648 DTWN4248 DTWN4848 Ventilator Kits Interior Exterior DIV300/440 DEV900/DIL900 DIV300/440 DEV900/1200/DIL900/1200 DIV440 DEV900/1200/DIL900/1200 DIV880 DEV1200/1500**/DIL1200 VIV300/600/1200* VEV900/1200*/DIL900/1200 VIV300/600/1200* VEV900/1200*/DIL900/1200 VIV600/1200* VEV900/1200*/DIL900/1200 VIV1200* VEV1200/1500**/DIL1200 Duct Size Interior Exterior 7" (17.8 cm) 10" (25.4 cm) 7" (17.8 cm) 10" (25.4 cm) 7" (17.8 cm) 10" (25.4 cm) 10" (25.4 cm) 10" (25.4 cm) 7" (17.8 cm) 10" (25.4 cm) 7" (17.8 cm) 10" (25.4 cm) 7" (17.8 cm) 10" (25.4 cm) 10" (25.4 cm) 10" (25.4 cm) Max. Amps Interior Exterior 1.7/3.2 6.6 1.7/3.2 6.6 3.2 6.6 5.6 4.3/5.1 2.4/4.6/6.6 6.6/3.9 2.4/4.6/6.6 6.6/3.9 4.6/6.6 6.6/3.9 7.0 4.3/5.1 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Note: Maximum amp rating for hoods includes recommended ventilator kit rating. All products must be hard wired with two-wire ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods. PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - INFORMATION SUBJECT TO CHANGE