Viking QSC200SS Specs - Page 5
OUTDOOR-COOKING, Installation Requirements - direct
View all Viking QSC200SS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Installation Requirements OUTDOOR-COOKING C4™ Charcoal Ceramic Cooking Capsule™ & C4™ Cooker Cart VCQS001 C4™ Cooker w/QSC200 20"W. C4 Cooker Cart VCQS001 C4™ Cooker w/QSC300 30"W. C4 Cooker Cart VCQS001 C4™ Cooker w/QSC412 41"W. C4 Cooker Cart w/Side Burners UTILITY REQUIREMENTS GAS (41"W. QSC412 models only) • Not applicable for QSC200/300 models Surface burner rating • Two grated grill burners, each @ 15,000 BTU (4.4 kW) Nat./ 13,500 BTU LP (4.0 kW) Fixed piping installations* • Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1. • An installer-supplied gas shutoff valve must be installed in an easily accessible location. All installer-supplied parts must conform to local codes. • Must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa). Natural gas models • Water column pressure o Operating pressure-4.0" WCP o Supply pressure of 6" - 14" WCP o If incoming pressure exceeds 14" WCP, a step-down regulator is required. • Accepts standard residential 1/2" (1.3 cm) ID gas service line; 1/2" (1.3 cm) NPT male with 7/8" (2.2 cm) flare adapter. o If using a Viking GSH12 flexible hose, remove the 1/2" (1.3 cm) flare adapter and attach hose to the 7/8" (2.2 cm) male flare on the regulator assembly. LP/propane models • Water column pressure o Operating pressure-10" WCP o Supply pressure of 11" - 14" WCP (for fixed piping installations) o If incoming pressure exceeds 14" WCP, a step-down regulator is required. • Accepts standard residential 1/2" (1.3 cm) ID gas service line; 1/2" (1.3 cm) NPT male with 3/8" (0.95) flare adapter. LP/propane tank installations • Water column pressure o Operating pressure-10" WCP o Includes high-capacity hose/regulator assembly for connection to a standard 5-gal./20-lb. (approx. 12" diameter/18"\H.) LP/propane gas cylinder equipped with a Type 1, QCC-1 connector • The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor cooking appliance. • The cylinder must be provided with a shut-off valve terminating in an LP/propane gas supply cylinder valve outlet specified. • The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device). ELECTRICAL • Not applicable for QSC200/300 models • 9-volt DC battery for electronic ignition (QSC412 model (side burners)) PLUMBING Not applicable * For fixed pipe fuel installations, remember to place the installer-supplied gas valve in an accessible location. Cabinet proximity The cart can be installed directly adjacent to side cabinets. There is 0" side clearance to non-combustible and combustible surfaces. Maintain a minimum of 6" (15.2 cm) from the back of the unit to allow cooker dome to open fully. PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 RELEASED 12/1/07 © 2 0 0 7 V R C - INFORMATION SUBJECT TO CHANGE