Viking RVGC33615BSS LP/Propane Conversion Kit - RDLPKC - Installation Instruct - Page 1

Viking RVGC33615BSS Manual

Page 1 highlights

LP Conversion Kit Instructions for D3 / 3 Series Gas Cooktops WARNING The conversion must be performed by a qualified installer or gas supplier in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. Failure to follow ALL instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for this conversion. Converting the Surface Burners 1. Remove the top grates, burner caps, and burner heads. WARNING If you attempt to measure the inner cone of the flame, please use caution as burns could result. The pressure regulator and the burner orifices are set for Natural gas. To use Liquid Propane gas, the regulator and burner orifices must be converted. To covert the range to LP gas, follow these instructions: 1. Disconnect all electrical power at the main circuit breaker or fuse box. 2. Shut off the gas supply to the range by closing the manual shut-off valve. Converting the Pressure Regulator 1. Locate the pressure regulator which can be found underneath the cooktop on the back right hand side, if the unit has already been installed, otherwise it will be packed separately with the unit. 2. Unscrew the hex nut cap from the top of the regulator. 3. Unsnap the plastic plunger from the hex nut. 4. Reverse the plunger and reinstall onto the hex nut by pressing firmly. Note: Plunger is marked "Nat" and "LP". Converted fuel type will be shown on the lower portion of the plunger. Note: To convert the oven back to Natural gas, reverse the instructions given for making the LP gas adjustments. Note: When the LP/Propane conversion is finished, complete the enclosed conversion label and place it next to the rating label. 2. Using a 9/32" or 7 mm nut driver remove the top burner orifices. These may be accessed through the opening in the burner base. Note: Save these orifices for future conversion back to Natural gas. 3. Locate the proper LP surface burner orifices included with the kit according to the chart listed below. Burner Left front/Left rear Center Hi Center Low Right front Right rear BTU Rate 9,000 15,000 2,000 10,000 5,000 Orifice Size 0.90 1.09 0.45 0.94 0.65 4. Install the orifices in their correct location. To prevent leakage, make sure the orifice spuds are securely screwed into the burner base. In some cases, foreign particles in the gas line may cause an orange flame at first but this will soon disappear. NAT Conversion Kit Instructions for D3 /3 Series Gas Cooktops WARNING The conversion must be performed by a qualified installer or gas supplier in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. Failure to follow ALL instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for this conversion. WARNING If you attempt to measure the inner cone of the flame, please use caution as burns could result. The pressure regulator and the burner orifices are set for LP/Propanel gas. To use Natural gas, the regulator and burner orifices must be converted. To covert the range to NAT gas, follow these instructions: 1. Disconnect all electrical power at the main circuit breaker or fuse box. 2. Shut off the gas supply to the range by closing the manual shut-off valve. Converting the Pressure Regulator 1. Locate the pressure regulator which can be found underneath the cooktop on the back right hand side, if the unit has already been installed, otherwise it will be packed separately with the unit. 2. Unscrew the hex nut cap from the top of the regulator. 3. Unsnap the plastic plunger from the hex nut. 4. Reverse the plunger and reinstall onto the hex nut by pressing firmly. Note: Plunger is marked "Nat" and "LP". Converted fuel type will be shown on the lower portion of the plunger. Note: To convert the oven back to LP gas, reverse the instructions given for making the LP gas adjustments. Converting the Surface Burners 1. Remove the top grates, burner caps, and burner heads. 2. Using a 9/32" or 7 mm nut driver remove the top burner orifices. These may be accessed through the opening in the burner base. Note: Save these orifices for future conversion back to LP gas. 3. Locate the proper natural surface burner orifices included with the kit according to the chart listed below. Burner Left front/Left rear Center Hi Center Low Right front Right rear BTU Rate 9,100 17,000 2,000 12,000 5,000 Orifice Size 1.35 1.88 0.53 1.52 0.99 4. Install the orifices in their correct location. To prevent leakage, make sure the orifice spuds are securely screwed into the burner base. In some cases, foreign particles in the gas line may cause an orange flame at first but this will soon disappear. Note: When the natural conversion is finished, complete the enclosed conversion label and place it next to the rating label. F21021C EN VIKING RANGE, LLC 111 Front Street • Greenwood, Mississippi 38930 USA • (662) 455-1200 (041014)

  • 1
  • 2

The pressure regulator and the burner orifices are set for
LP/Propanel gas. To use Natural gas, the regulator and burner
orifices must be converted.
To covert the range to NAT gas, follow these instructions:
1.
Disconnect all electrical power at the main circuit breaker or
fuse box.
2.
Shut off the gas supply to the range by closing the manual
shut-off valve.
Converting the Pressure Regulator
1.
Locate the pressure regulator which can be found underneath
the cooktop on the back right hand side, if the unit has
already been installed, otherwise it will be packed separately
with the unit.
2.
Unscrew the hex nut cap from the top of the regulator.
3.
Unsnap the plastic plunger from the hex nut.
4.
Reverse the plunger and reinstall onto the hex nut by
pressing firmly.
Note: Plunger is marked “Nat” and “LP”. Converted fuel type will
be shown on the lower portion of the plunger.
Note: To convert the oven back to LP gas, reverse the
instructions given for making the LP gas adjustments.
Note: When the natural conversion is finished,
complete the enclosed conversion label and place
it next to the rating label.
Converting the Surface Burners
1.
Remove the top grates, burner caps, and burner heads.
2.
Using a 9/32” or 7 mm nut driver remove the top burner
orifices. These may be accessed through the opening in the
burner base.
Note: Save these orifices for future conversion back to LP gas.
3.
Locate the proper natural
surface burner orifices included
with the kit according to the
chart listed below.
4.
Install the orifices in their correct location. To prevent leakage,
make sure the orifice spuds are securely screwed into the
burner base. In some cases, foreign particles in the gas line
may cause an orange flame at first but this will soon
disappear.
WARNING
The conversion must be performed by a qualified
installer or gas supplier in accordance with the
manufacturer’s instructions and all codes and
requirements of the authority having jurisdiction. Failure to
follow
ALL
instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for this conversion.
Burner
BTU Rate
Orifice Size
Left front/Left rear
9,100
1.35
Center Hi
17,000
1.88
Center Low
2,000
0.53
Right front
12,000
1.52
Right rear
5,000
0.99
NAT Conversion Kit Instructions for D3 /3 Series
Gas Cooktops
WARNING
If you attempt to measure the inner cone of the
flame, please use caution as burns could result.
The pressure regulator and the burner orifices are set for Natural
gas. To use Liquid Propane gas, the regulator and burner orifices
must be converted.
To covert the range to LP gas, follow these instructions:
1.
Disconnect all electrical power at the main circuit breaker or
fuse box.
2.
Shut off the gas supply to the range by closing the manual
shut-off valve.
Converting the Pressure Regulator
1.
Locate the pressure regulator which can be found underneath
the cooktop on the back right hand side, if the unit has
already been installed, otherwise it will be packed separately
with the unit.
2.
Unscrew the hex nut cap from the top of the regulator.
3.
Unsnap the plastic plunger from the hex nut.
4.
Reverse the plunger and reinstall onto the hex nut by
pressing firmly.
Note: Plunger is marked “Nat” and “LP”. Converted fuel type will
be shown on the lower portion of the plunger.
Note: To convert the oven back to Natural gas, reverse the
instructions given for making the LP gas adjustments.
Note: When the
LP/Propane
conversion is
finished,
complete the
enclosed
conversion label
and place it next
to the rating
label.
Converting the Surface Burners
1.
Remove the top grates, burner caps, and burner heads.
2.
Using a 9/32” or 7 mm nut driver remove the top burner
orifices. These may be accessed through the opening in the
burner base.
Note: Save these orifices for future conversion back to Natural gas.
3.
Locate the proper LP surface
burner orifices included with the
kit according to the chart listed
below.
4.
Install the orifices in their correct location. To prevent leakage,
make sure the orifice spuds are securely screwed into the
burner base. In some cases, foreign particles in the gas line
may cause an orange flame at first but this will soon disappear.
WARNING
The conversion must be performed by a qualified
installer or gas supplier in accordance with the
manufacturer’s instructions and all codes and
requirements of the authority having jurisdiction. Failure to
follow
ALL
instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for this conversion.
Burner
BTU Rate
Orifice Size
Left front/Left rear
9,000
0.90
Center Hi
15,000
1.09
Center Low
2,000
0.45
Right front
10,000
0.94
Right rear
5,000
0.65
LP Conversion Kit Instructions for D3 / 3 Series
Gas Cooktops
WARNING
If you attempt to measure the inner cone of the
flame, please use caution as burns could result.
F21021C EN
(041014)
VIKING RANGE, LLC
111 Front Street • Greenwood, Mississippi
38930 USA • (662) 455-1200