Viking VCBB363RSS Installation Instructions - Page 21

Hinge Adjustment

Page 21 highlights

Hinge Adjustment 5 2 1 Remove four side screws and remove unit top. 7 1 6 Front of unit 2 1 3 Loosen the four hinge screws. Adjust door. Retighten four hinge screws. 2 Replace unit top. Replace four side screws. 8a 8b Wall 2x4 Refrigerator Attach one 2x4 to wall stud (refer to dimensions page for exact location). Wall 2x4 Refrigerator If needed, depending on cabinet and depth, attach second 2x4 to first 2x4. 40 9 10a 3" Plug in power cord to verify operation. NOTE: Make sure power switch is in the "On" Position. 10b Place unit within 3" of being flush with cabinets. NOTE: To avoid cabinet damage, place cardboard between cabinets and unit. When moving unit, do not crimp, kink or crush water supply line. 11 Carefully move unit until semi flush with cabinet (depending on unit). 12 Pull supply tubing forward under unit. NOTE: DO NOT use plastic water lines. 13 Flush water line by running two quarts of water into a bucket. Turn water off. Connect supply tube to water valve using a 1/2" wrench. NOTE: DO NOT overtighten. 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

41
9
3”
3”
3”
10a
Plug in power cord to verify operation.
NOTE:
Make sure power switch is in the “On” Position.
Place unit within 3” of being flush with cabinets.
NOTE:
To avoid cabinet damage, place cardboard
between cabinets and unit. When moving unit, do not
crimp, kink or crush water supply line.
10b
11
Carefully move unit until semi flush with cabinet
(depending on unit).
Pull supply tubing forward under unit.
NOTE:
DO NOT use plastic water lines.
12
13
Flush water line by running two quarts of water
into a bucket. Turn water off.
Connect supply tube to water valve using
a 1/2” wrench.
NOTE:
DO NOT overtighten.
40
Remove four side screws and remove unit top.
Loosen the four hinge screws. Adjust door.
Retighten four hinge screws.
Replace unit top. Replace four side screws.
Attach one 2x4 to wall stud (refer to dimensions page
for exact location).
If needed, depending on cabinet and depth,
attach second 2x4 to first 2x4.
2
1
5
Front of unit
2
1
3
6
1
2
7
8a
Wall
2x4
Refrigerator
8b
Wall
2x4
Refrigerator
Hinge Adjustment