HCaebadinleinteInformation (with Flush Mount Trim) Flush Mount Installation with Standard Cabinets 1/4" (0.25 cm) Offset in Finished Wall 23-7/8" (60.6 cm) 24-5/8" (62.5 cm) 1-3/4" (4.4 cm) 26-1/2" (67.3 cm) 26-1/4" (66.7 cm) Finished Wall 24" (61.0 cm) 24-3/4" (62.9 cm) Flush Side trim Face of cabinet frame 3/4" (.6 cm) * Face of door/drawer *The face of the door skin needs to be on the same plane, flush with the cabinets. If the door face is pushed in past the surface of the cabinet, the door could run into cabinetry when it is in the full open position. The hinge stop needs to be placed at 90 or 110 degrees. Flush Mount Installation with Custom Cabinets 1/8" (0.3 cm) 23-7/8" (60.6 cm) 24-5/8" (62.5 cm) 26-1/2" (67.3 cm) 26-1/4" (66.7 cm) Finished Wall 25-5/8" (65.1 cm) 26-3/8" (67.0 cm) Flush Side trim 1/2" (1.3 cm) Face of cabinet frame Face of stainless steel door * Face of door/drawer *The face of the door skin needs to be on the same plane, flush with the cabinets. If the door face is pushed in past the surface of the cabinet, the door could run into cabinetry when it is in the full open position. The hinge stop needs to be placed at 90 or 110 degrees. 3/4" (.6 cm) 15