Viking VDB200SS Specs - Page 4
KITCHEN CLEANUP, Built-In 24W. Dishwasher 200, Installation Requirements
View all Viking VDB200SS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
KITCHEN CLEANUP Built-In 24"W. Dishwasher 200 UTILITY REQUIREMENTS GAS Not applicable ELECTRICAL • 120V/60 Hz • Maximum amp usage-15.0 amps • Water-heating element rating- 1,200 watts Installation Requirements ACCESS REQUIREMENTS VDB200 Professional Built-In Dishwasher DDB200 Designer Built-In Dishwasher PLUMBING • 120°F (49°C) hot water recommended; dishwasher will, however, perform properly with cold water* • Inlet water pressure operating range- 10 - 125 psi (0.69 - 8.62 bar) • Five foot (1.5 m) braided stainless steel water line with 3/8" (0.95 cm) compression fitting supplied with dishwasher • Seven-foot (2.13 m) 1/2" (1.3 cm) ID "crimp-proof" flexible drain hose with clamp attached to dishwasher; connections provided for 5/8" (1.5 cm), 3/4" (1.9 cm), or 1" (2.5 cm) cut as required • High loop of drain hose required; min. height from floor- 20" (50.8 cm) • Check local codes for drain air gap requirement *Cycle times will be extended (612.04"cm) (612.04"cm) 33((885469""..t40momccamminx)).. FDB200 Custom Front Built-In Dishwasher See Custom Panels section for more information and additional specifications. A 2" cut-out is required for water supply and discharge lines. Cutout width Cutout height Cutout depth All models 24" (61.0 cm) 34" (86.4 cm) min. to 35" (89.0 cm) max. 24" (61.0 cm) PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 4/29/11 © 2 0 1 1 V R C - INFORMATION SUBJECT TO CHANGE