Viking VDD5480 VDVE1200 - 1200 CFM Exterior Power Ventilator - Installation In - Page 1

Viking VDD5480 Manual

Page 1 highlights

MODEL VDVE1200 EXTERIOR MOUNTED BLOWER FOR USE WITH MODELS VDD5300, CVDD5300, VDD5360, CVDD5360, VDD5450, CVDD5450, VDD5480, CVDD5480 DOWNDRAFT VENTILATORS. READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURYTO PERSONS,OBSERVETHE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer or your distributor. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. WARNING 5. When cutting or drilling into wall, or ceiling, do not damage electrical wiring or other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce risk of fire, use only metal ductwork. 8. This unit must be grounded. CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive material and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc.off power unit. 3. Please read specification label on product for further information and requirements. 4. Electrical circuit, including speed control, (if used), must be rated 6 AMPS minimum. Blower Dimensions 22 x 30.828 x 12.724 SPECIFICATIONS MODEL VOLTS AMPS CFM DUCT SIZE VDVE1200 120 3.0 1200 10" DIA. PLAN THE INSTALLATION ALL INSTALLATIONS 1. Locate the blower so the length of the duct run and number of elbows needed are kept to a minimum. 2. Where possible, blower should be centered between wall studs or roof rafters. 3. Avoid pipes, wires, or other ductwork that may be running through the wall. MODEL VVDEVDEV11220000 EEXXTTEERRIIOORR BBLLOOWWEERR 10" ROUND DUCT TO DOWNDRAFT TYPICAL ROOF MOUNTED INSTALLATION 10" ROUND DUCT TO DOWNDRAFT MMOODDEELL VVEDDVVE11220000 EEXXTTEERRIOIORR BBLLOOWWEERR TYPICAL WALL MOUNTED INSTALLATION INSTALLER: Leave This Manual With The Homeowner HOMEOWNER: Use And Care Information On Page 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

READ AND SAVE THESE INSTRUCTIONS
MODEL VDVE1200
EXTERIOR MOUNTED BLOWER
FOR USE WITH MODELS VDD5300, CVDD5300, VDD5360, CVDD5360, VDD5450,
CVDD5450, VDD5480, CVDD5480 DOWNDRAFT VENTILATORS.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURYTO PERSONS, OBSERVETHE FOLLOWING:
1.
Use this unit only in the manner intended by the manu-
facturer. If you have questions, contact the manufacturer
or your distributor.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3.
Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National
Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
CAUTION
1.
For general ventilating use only. Do not use to exhaust haz-
ardous or explosive material and vapors.
2.
To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3.
Please read specification label on product for further informa-
tion and requirements.
4.
Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
PLAN THE
INSTALLATION
1.
Locate the blower so the
length of the duct run and
number of elbows needed
are kept to a minimum.
2. Where possible, blower
should be centered be-
tween wall studs or roof
rafters.
3.
Avoid pipes, wires, or other
ductwork that may be run-
ning through the wall.
ALL
INSTALLATIONS
MODEL
VOLTS
AMPS
CFM
DUCT SIZE
VDVE1200
120
3.0
1200
10"
DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
TYPICAL ROOF MOUNTED INSTALLATION
TYPICAL WALL MOUNTED INSTALLATION
5. When cutting or drilling into wall, or ceiling, do not dam-
age electrical wiring or other hidden utilities.
6.
Ducted fans must always be vented to the outdoors.
7.
To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
WARNING
10" ROUND
DUCT
TO
DOWNDRAFT
10" ROUND DUCT
TO
DOWNDRAFT
Blower Dimensions
22
x 30.828
x 12.724
MODEL VDVE1200
EXTERIOR BLOWER
MODEL
VDVE1200
EXTERIOR
BLOWER