Viking VGBQ4103RE2NSS Specs - Page 6
VGBQ410-3RE2, E-Series, Three-Burner All-Grill, VGBQ412-2RE2, Two-Burner Grill, w/Side Burners,
View all Viking VGBQ4103RE2NSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
OUTDOOR-COOKING 41"W. Ultra-Premium T-Series/E-Series Gas Grill Installation Requirements VGBQ410-3RE2* E-Series Three-Burner All-Grill VGBQ412-2RE2* E-Series Two-Burner Grill w/Side Burners VGIQ410-3RT/E2* T-Series/E-Series Three-Burner All-Grill (inc. TruSear™ Burner) UTILITY REQUIREMENTS GAS Fixed piping installations • Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1. • An installer-supplied gas shutoff valve must be installed in an easily accessible location. All installer-supplied parts must conform to local codes. • Must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa). Natural gas models • Water column pressure o Operating pressure-4.0" WCP o Supply pressure of 6" - 14" WCP o If incoming pressure exceeds 14" WCP, a step-down regulator is required. • Accepts standard residential 1/2" (1.3 cm) ID gas service line; 1/2" (1.3 cm) NPT male with 7/8" (2.2 cm) flare adapter. VGBQ410-3RE2 Burner rating Standard SS grill burners (each) GourmetGlo™ rotisserie burner Side grill burners (each) TruSear infrared burner o If using a Viking GSH12 flexible hose, remove the 1/2" (1.3 cm) flare adapter and attach hose to the 7/8" (2.2 cm) male flare on the regulator assembly. LP/propane models • Water column pressure o Operating pressure-10" WCP o Supply pressure of 11" - 14" WCP (for fixed piping installations) o If incoming pressure exceeds 14" WCP, a step-down regulator is required. • Accepts standard residential 1/2" (1.3 cm) ID gas service line; 1/2" (1.3 cm) NPT male with 3/8" (0.95) flare adapter. LP/propane tank installations • Water column pressure o Operating pressure-10" WCP • Includes high-capacity hose/regulator assembly for connection to a standard 5gal./20-lb. (approx. 12" diameter/18"H.) LP/propane gas cylinder equipped with a Type 1, QCC-1 connector o The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor cooking appliance. o The cylinder must be provided with a shut-off valve terminating in an LP/propane gas supply cylinder valve outlet specified. VGBQ412-2RE2 o The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device). ELECTRICAL • T-Series models o 9-volt DC battery for electronic ignition o 2' (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor. • 120 VAC/60 Hz o Rotisserie motor max. amp usage-6.0 • E-Series models o 3' (91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill • 120 VAC/60 Hz o 120 VAC/60 Hz o Grill max. amp usage • VGBQ/VGIQ410-2.2 • VGBQ412-2.3 o 2' (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor. • 120 VAC/60 Hz o Rotisserie motor max. amp usage-6.0 PLUMBING Not applicable VGIQ410-3RT/E2 25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP (T-Series) 29,000 BTU (7.3 kW) Nat./28,000 BTU (6.5 kW) LP (E-Series) 15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP 15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP 30,000 BTU (8.8 kW) Nat./LP PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 5/16/11 © 2 0 1 1 V R C - INFORMATION SUBJECT TO CHANGE