Viking VGBQ4122RE2NSS Specs - Page 6

VGBQ410-3RE2, E-Series, Three-Burner All-Grill, VGBQ412-2RE2, Two-Burner Grill, w/Side Burners,

Page 6 highlights

OUTDOOR-COOKING 41"W. Ultra-Premium T-Series/E-Series Gas Grill Installation Requirements VGBQ410-3RE2* E-Series Three-Burner All-Grill VGBQ412-2RE2* E-Series Two-Burner Grill w/Side Burners VGIQ410-3RT/E2* T-Series/E-Series Three-Burner All-Grill (inc. TruSear™ Burner) UTILITY REQUIREMENTS GAS Fixed piping installations • Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1. • An installer-supplied gas shutoff valve must be installed in an easily accessible location. All installer-supplied parts must conform to local codes. • Must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa). Natural gas models • Water column pressure o Operating pressure-4.0" WCP o Supply pressure of 6" - 14" WCP o If incoming pressure exceeds 14" WCP, a step-down regulator is required. • Accepts standard residential 1/2" (1.3 cm) ID gas service line; 1/2" (1.3 cm) NPT male with 7/8" (2.2 cm) flare adapter. VGBQ410-3RE2 Burner rating Standard SS grill burners (each) GourmetGlo™ rotisserie burner Side grill burners (each) TruSear infrared burner o If using a Viking GSH12 flexible hose, remove the 1/2" (1.3 cm) flare adapter and attach hose to the 7/8" (2.2 cm) male flare on the regulator assembly. LP/propane models • Water column pressure o Operating pressure-10" WCP o Supply pressure of 11" - 14" WCP (for fixed piping installations) o If incoming pressure exceeds 14" WCP, a step-down regulator is required. • Accepts standard residential 1/2" (1.3 cm) ID gas service line; 1/2" (1.3 cm) NPT male with 3/8" (0.95) flare adapter. LP/propane tank installations • Water column pressure o Operating pressure-10" WCP • Includes high-capacity hose/regulator assembly for connection to a standard 5gal./20-lb. (approx. 12" diameter/18"H.) LP/propane gas cylinder equipped with a Type 1, QCC-1 connector o The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor cooking appliance. o The cylinder must be provided with a shut-off valve terminating in an LP/propane gas supply cylinder valve outlet specified. VGBQ412-2RE2 o The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device). ELECTRICAL • T-Series models o 9-volt DC battery for electronic ignition o 2' (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor. • 120 VAC/60 Hz o Rotisserie motor max. amp usage-6.0 • E-Series models o 3' (91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill • 120 VAC/60 Hz o 120 VAC/60 Hz o Grill max. amp usage • VGBQ/VGIQ410-2.2 • VGBQ412-2.3 o 2' (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor. • 120 VAC/60 Hz o Rotisserie motor max. amp usage-6.0 PLUMBING Not applicable VGIQ410-3RT/E2 25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP (T-Series) 29,000 BTU (7.3 kW) Nat./28,000 BTU (6.5 kW) LP (E-Series) 15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP 15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP 30,000 BTU (8.8 kW) Nat./LP PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 5/16/11 © 2 0 1 1 V R C - INFORMATION SUBJECT TO CHANGE

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

VGBQ410-3RE2*
E-Series
Three-Burner All-Grill
VGBQ412-2RE2*
E-Series
Two-Burner Grill
w/Side Burners
VGIQ410-3RT/E2*
T-Series/E-Series
Three-Burner All-Grill
(inc. TruSear™ Burner)
GAS
Fixed piping installations
• Check with local gas utility
company or with local codes
for instructions on installing
gas supply lines. All gas
connections should be made
by a competent technician and
in accordance with local codes
and or ordinances. In the
absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.
• An installer-supplied gas shut-
off valve must be installed in
an easily accessible location.
All installer-supplied parts
must conform to local codes.
• Must be isolated from the gas
supply piping system by
closing its individual manual
shut-off valve during any
pressure testing of that system
at test pressures equal to or
less than 1/2 psi (3.5 kPa).
Natural gas models
Water column pressure
o Operating pressure—4.0"
WCP
o Supply pressure of 6" – 14"
WCP
o If incoming pressure exceeds
14" WCP, a step-down
regulator is required.
Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare adapter.
o If using a Viking GSH12
flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.
LP/propane models
Water column pressure
o Operating pressure—10” WCP
o Supply pressure of 11” – 14”
WCP (for fixed piping
installations)
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.
LP/propane tank installations
Water column pressure
o Operating pressure—10”
WCP
Includes high-capacity
hose/regulator assembly for
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector
o The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.
o The cylinder must be
provided with a shut-off
valve terminating in an
LP/propane gas supply
cylinder valve outlet
specified.
o The cylinder supply system
must be arranged for vapor
withdrawal and provided
with a listed OPD (overfilling
prevention device).
ELECTRICAL
T-Series models
o 9-volt DC battery for
electronic ignition
o 2’ (61.0 cm) power cord
supply cord with 3-prong
grounded plug attached to
rotisserie motor.
120 VAC/60 Hz
o Rotisserie motor max. amp
usage—6.0
E-Series models
o 3’ (91.4 cm) power cord
supply cord with 3-prong
grounded plug attached to
grill
120 VAC/60 Hz
o 120 VAC/60 Hz
o Grill max. amp usage
VGBQ/VGIQ410—2.2
VGBQ412—2.3
o 2’ (61.0 cm) power cord
supply cord with 3-prong
grounded plug attached to
rotisserie motor.
120 VAC/60 Hz
o Rotisserie motor max. amp
usage—6.0
PLUMBING
Not applicable
UTILITY
REQUIREMENTS
OUTDOOR—COOKING
41”W. Ultra-Premium T-Series/E-Series Gas Grill
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM
1-888-VIKING1
Installation Requirements
VGBQ410-3RE2
VGBQ412-2RE2
VGIQ410-3RT/E2
Burner rating
Standard SS grill burners (each)
25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP (T-Series)
29,000 BTU (7.3 kW) Nat./28,000 BTU (6.5 kW) LP (E-Series)
GourmetGlo™ rotisserie burner
15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP
Side grill burners (each)
15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP
TruSear infrared burner
3
0,000 BTU (8.8 kW) Nat./LP
REVISED 5/16/11
© 2 0 1 1 V R C — INFORMATION SUBJECT TO CHANGE