Viking VGRT5366BSS Built-in Surface Cooking - Page 26

Basic specifications - Gas cooktops

Page 26 highlights

Basic specifications - Gas cooktops Description Overall Width Overall Height G A S 3 0 " and 3 6 " W I D E cooktops VGSU104 VGSU164 30 3/4" (78.1 cm) 36 3/4" (93.3 cm) 5" (12.7 cm) Overall Depth 21" (53.3 cm) Cutout Width Cutout Height Cutout Depth Gas Requirements Electrical Requirements 26 7/8" (68.3 cm) minimum 29 7/8" (75.9 cm) maximum 34 3/8" (87.3 cm) minimum 35 7/8" (91.1 cm) maximum 2 1/2" (6.4 cm) minimum 18 5/8" (47.3 cm) minimum 20 1/8" (51.1 cm) maximum Accepts standard residential 1/2" (1.3 cm) ID gas service line. Order either natural gas or LP propane; to field convert from natural to LP propane, order optional LP conversion kit. 120VAC/60Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product Maximum Amp Usage Surface Burner Rating 2.0 amps Left Front: 16,000 BTU NAT./15,500 BTU LP (4.8 kW NAT./4.65 kW LP) Left Rear: 12,000 BTU NAT./11,500 BTU LP (3.6 kW NAT./3.45 kW LP) Right Front: 6,000 BTU NAT./5,500 BTU LP (1.8 kW NAT./1.65 kW LP) Right Rear: 8,000 BTU NAT./7,500 BTU LP (2.4 kW NAT./2.25 kW LP) Left Front: 16,000 BTU NAT./15,500 BTU LP (4.8 kW NAT./4.65 kW LP) Left Rear, Center Front, and Center Rear: 12,000 BTU NAT./11,500 BTU LP (3.6 kW NAT./3.45 kW LP) Right Front: 6,000 BTU NAT./5,500 BTU LP (1.8 kW NAT./1.65 kW LP) Right Rear: 8,000 BTU NAT./7,500 BTU LP (2.4 kW NAT./2.25 kW LP) Approximate Shipping Weight 67 lb. (30.2 kg) 80 lb. (36.0 kg) 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

18 5/8" (47.3 cm) minimum
20 1/8" (51.1 cm) maximum
2 1/2" (6.4 cm) minimum
21" (53.3 cm)
Basic specifications – Gas cooktops
VGSU104
Overall Width
30 3/4" (78.1 cm)
Overall Height
Overall Depth
Cutout Width
Cutout Height
Description
GAS
30"
AND
36"
WIDE
COOKTOPS
5" (12.7 cm)
26 7/8" (68.3 cm) minimum
29 7/8" (75.9 cm) maximum
Cutout Depth
Gas Requirements
VGSU164
36 3/4" (93.3 cm)
34 3/8" (87.3 cm) minimum
35 7/8" (91.1 cm) maximum
Accepts standard residential 1/2" (1.3 cm) ID gas service line. Order either natural gas or LP propane; to field
convert from natural to LP propane, order optional LP conversion kit.
26
Electrical Requirements
Maximum Amp Usage
Surface Burner Rating
Approximate Shipping
Weight
67 lb. (30.2 kg)
80 lb. (36.0 kg)
Left Front:
16,000 BTU NAT./15,500 BTU LP
(4.8 kW NAT./4.65 kW LP)
Left Rear:
12,000 BTU NAT./11,500 BTU LP
(3.6 kW NAT./3.45 kW LP)
Right Front:
6,000 BTU NAT./5,500 BTU LP
(1.8 kW NAT./1.65 kW LP)
Right Rear:
8,000 BTU NAT./7,500 BTU LP
(2.4 kW NAT./2.25 kW LP)
Left Front:
16,000 BTU NAT./15,500 BTU LP
(4.8 kW NAT./4.65 kW LP)
Left Rear, Center Front, and Center Rear:
12,000 BTU NAT./11,500 BTU LP
(3.6 kW NAT./3.45 kW LP)
Right Front:
6,000 BTU NAT./5,500 BTU LP
(1.8 kW NAT./1.65 kW LP)
Right Rear:
8,000 BTU NAT./7,500 BTU LP
(2.4 kW NAT./2.25 kW LP)
120VAC/60Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product
2.0 amps