Viking VIFB530LSS Installation Instructions - Page 23

Dual 30 & 36 Designer

Page 23 highlights

Cutout Dimensions (612.04"cm) Dual 30" & 36" Designer See Anti-Tip board installation Electric Outlet Location (15.62"cm) (22.99"cm) (22.99"cm) (ao2np1t8e0i-nt.25iipn-cg7bm/oh8)aemr"igdihn&t. (a2on1p8t3ei-4.nt5i-ipn1cgbm/oh1)ae6mrigd"ah&xt. (71836-.34/c8m") Water Line Entry Area Note: Cutout opening shown with All Freezer model on left. Reverse water line entry if All Freezer model is on right. (167.66c6m") (15.5/8c"m) (719-.54/c8m") (7.63"cm) (617-.31/c4m") (9.32-c5m/)8" (1667.66"cm) (15.5/8c"m) (271.30-c3m/)4" (261.07 -c1m/)2" waOteprtiloinnealefnltoroyr (1.55c/m8)" (2.15"cm) 44 Anti-Tip Dimensions Dual 30" & 36" Designer (2at0no71tbi.9-6to-iptc3tmob/m8)oma"ordifn. (2at0no48t.bi06-to-icpt1tmob/m)2oma"oradfx. Anti-Tip Location (732.79"cm) 1(3-.81/c2m") 3(8-.91/c2m") (582.43"cm) One 2"x 4" mounting board per unit 1-1/2" (3.8 cm) x 3-1/2" (8.9 cm) Note: If unit is installed deeper than 24" (61.0 cm), then shim behind the mounting boards by the difference. Bottom of anti-tip board is 3-7/8" (9.8 cm) below opening height. Note: Top of unit must be placed firmly under anti-tip board. Note: Dimensions shown for 36" AF/AR model on the left. Reverse mounting boards if units are installed on the right. 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

79–3/8”
(201.6 cm) min.
to bottom of
anti-tip board
80–1/2”
(204.6 cm) max.
to bottom of
anti-tip board
One 2”x 4” mounting board per unit
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Note:
If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting boards by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note:
Top of unit must be placed firmly under anti-tip board.
Note:
Dimensions shown for 36” AF/AR model on the left.
Reverse mounting boards if units are installed on the right.
Anti-Tip Location
29”
(73.7 cm)
3–1/2”
(8.9 cm)
1–1/2”
(3.8 cm)
23”
(58.4 cm)
Anti-Tip Dimensions
45
9”
(22.9 cm)
73–3/8”
(186.4 cm)
82–7/8”
(210.5 cm) min.
anti-tip board &
opening height
84–1/16”
(213.5 cm) max.
anti-tip board &
opening height
66”
(167.6 cm)
24”
(61.0 cm)
Electric Outlet Location
Water Line Entry Area
Note:
Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
66”
(167.6 cm)
6–3/4”
(17.1 cm)
7–5/8”
(19.4 cm)
3”
(7.6 cm)
5/8”
(1.5 cm)
5/8”
(1.5 cm)
10–1/2”
(26.7 cm)
5/8”
(1.5 cm)
10–3/4”
(27.3 cm)
3–5/8”
(9.2 cm
)
Optional floor
water line entry
1”
(2.5 cm
)
See Anti-Tip board installation
6”
(15.2 cm)
9”
(22.9 cm)
Cutout Dimensions
44
Dual 30” & 36” Designer
Dual 30” & 36” Designer