Viking VIRB304RSS Grille Kit Instructions - Page 10

Anti-Tip Dimensions, Cutout Dimensions

Page 10 highlights

Cutout Dimensions (612.04"cm) Dual 30" Professional & Professional Integrated See Anti-Tip board installation Electric Outlet Location (15.62"cm) (22.99"cm) (22.99"cm) ao(2np1tei80-nt.2i5ipn-cg7bm/oh8)aem"rigdihn&t. (ao2np18te3i-4nt.5i-ipn1cgb/moh1)ae6mrigd"ihn&t. (17836-.34/c8m") Water Line Entry Area Note: Cutout opening shown with All Freezer model on left. Reverse water line entry if All Freezer model is on right. ProMfeosdsieol(ns1a5Ol2nI.n4ly6tec0mg("1r)a5t51e.91d-c1m/2) " (15.5/8c"m) Professional (7(.71639-"c.54m/c8)m") (617-.31/c4m") In(1t5e(625g1.05r94a"1-ct.1em1/d)c2mM")odels Only (9.32-c5m/)8" (15.5/8c"m) (271.30-c3m/)4" (261.07 -c1m/)2" waOteprtiloinnealefnltoroyr (1.55c/m8)" (2.15"cm) Anti-Tip Dimensions Dual 30" Professional & Professional Integrated Professional Anti-Tip Location (2at0on71tbi.9-6ot-itpc3tmob/m8)oma"orfdin. (2at0on48tb.i06-ot-itcp1tmob/m)2oma"orafdx. Two 2"x 4" mounting boards per unit 3" (7.6 cm) x 3-1/2" (8.9 cm) (582.43"cm) (7.63"cm) 3(8-.91/c2m") (582.43"cm) Note: If unit is installed deeper than 24" (61.0 cm), then shim behind the anti-tip bracket by the difference. Professional Integrated Anti-Tip Location Bottom of anti-tip board is 3-7/8" (9.8 cm) below opening height. Note: Top of unit must b e placed firmly under anti-tip board. One 2"x 4" mounting board per unit 1-1/2" (3.8 cm) x 3-1/2" (8.9 cm) (582.43"cm) 1(3-.81/c2m") 3(8-.91/c2m") (582.43"cm) Note: If unit is installed deeper than 24" (61.0 cm), then shim behind the anti-tip bracket by the difference. 18 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

19
18
79–3/8”
(201.6 cm) min.
to bottom of
anti-tip board
80–1/2”
(204.6 cm) max.
to bottom of
anti-tip board
One 2”x 4” mounting board per unit
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Two 2”x 4” mounting boards per unit
3” (7.6 cm) x 3–1/2” (8.9 cm)
Note:
If unit is installed deeper than
24” (61.0 cm), then shim behind the anti-tip
bracket by the difference.
Note:
If unit is installed deeper than
24” (61.0 cm), then shim behind the anti-tip
bracket by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note:
Top of unit must be placed firmly under anti-tip board.
Professional
Anti-Tip Location
Professional Integrated
Anti-Tip Location
23”
(58.4 cm)
3–1/2”
(8.9 cm)
3”
(7.6 cm)
23”
(58.4 cm)
23”
(58.4 cm)
3–1/2”
(8.9 cm)
1–1/2”
(3.8 cm)
23”
(58.4 cm)
Anti-Tip Dimensions
9”
(22.9 cm)
73–3/8”
(186.4 cm)
82–7/8”
(210.5 cm) min.
anti-tip board &
opening height
84–1/16”
(213.5 cm) min.
anti-tip board &
opening height
59–1/2”
(151.1 cm)
60”
(152.4 cm)
Professional Integrated
Models Only
24”
(61.0 cm)
Electric Outlet Location
Water Line Entry Area
Note:
Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
59–1/2”
(151.1 cm)
60”
(152.4 cm)
Professional Integrated Models Only
6–3/4”
(17.1 cm)
7–5/8”
(19.4 cm)
3”
(7.6 cm)
5/8”
(1.5 cm)
5/8”
(1.5 cm)
10–1/2”
(26.7 cm)
5/8”
(1.5 cm)
10–3/4”
(27.3 cm)
3–5/8”
(9.2 cm
)
Optional floor
water line entry
1”
(2.5 cm
)
See Anti-Tip board installation
6”
(15.2 cm)
9”
(22.9 cm)
Cutout Dimensions
Dual 30” Professional & Professional Integrated
Dual 30” Professional & Professional Integrated