DrawerMicro Oven Measurements Clearances and Dimensions 1 Electrical outlet location 5" (6") Anti-Tip block 3 ¹⁄₂" 36" countertop height 4" 22 ¹⁄₈" opening Allow ¾" overlap. 23 ½" Allow ¾" min depth overlap. Allow overlap 14 opening 14 to bottom of Anti-Tip block Allow overlap Floor must support 100 lbs. 24" cabinet min. 19" to top of floor 2 15 ⁵⁄₈ " 4 1 23 ⁷⁄₈" 21 14 15" auto drawer opening 23 ³⁄₈" 1 ³⁄₄" door thickness DRAWERMICRO OVEN MEASUREMENTS: Figures 1 and 2 contain many DrawerMicro Oven measurements for reference when planning the drawer's location which can be installed below any electric or gas wall oven. It can also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach. Power cord access hole in cabinet should be a minimum 1½" diameter hole and deburred of all sharp edges. IMPORTANT: Always allow sufficient power cord length to the electrical outlet to prevent tension. DO NOT USE AN EXTENSION CORD. If the power supply cord is too short, have a qualified electrician or serviceman install an outlet near the appliance. Always check electrical codes for requirements. • Dimensions that are shown in figure 1 must be used. Given dimensions provide minimum clearance. Locate electrical outlet in the shaded area in the upper left-hand corner of the cutout. See figure 4. • Contact surface must be solid and level. Pay special attention to the floor on which the appliance will sit. The floor of the opening should be constructed of plywood strong enough to support the weight of the oven (about 100 pounds). • Check location where the DrawerMicro Oven will be installed for proper electrical supply. • Your appliance can be built into a cabinet or wall by itself or under a gas or electric wall oven. • Be sure that the clearance of the floor between the wall oven and the DrawerMicro Oven is a minimum of 2". • The microwave interior will easily accommodate a 9" x 13" oblong dish or a bag of microwave popcorn. Anti-Tip Block NORMAL INSTALLATION STEPS Anti-Tip Block Installation Instructions • To reduce the risk of tipping of the drawer, the Anti-Tip block must be properly installed located 14-13/16" above the floor on which the appliance will sit. The 6" Anti-Tip block must be provided by the installer. See figure 1. The Anti-Tip block prevents serious injury that might result from spilled hot liquids. E4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

E4
DrawerMicro Oven
Measurements
• Dimensions that are shown in figure
1
must
be used. Given dimensions provide minimum
clearance. Locate electrical outlet in the shaded
area in the upper left-hand corner of the cutout.
See figure
4
.
• Contact surface must be solid and level. Pay
special attention to the floor on which the
appliance will sit. The floor of the opening should
be constructed of plywood strong enough to
support the weight of the oven (about 100
pounds).
• Check location where the DrawerMicro Oven will
be installed for proper electrical supply.
• Your appliance can be built into a cabinet or wall
by itself or under a gas or electric wall oven.
• Be sure that the clearance of the floor between
the wall oven and the DrawerMicro Oven is a
minimum of 2".
• The microwave interior will easily accommodate
a 9" x 13" oblong dish or a bag of microwave
popcorn.
Anti-Tip Block
NORMAL INSTALLATION STEPS
Anti-Tip Block Installation Instructions
• To reduce the risk of tipping of the drawer, the
Anti-Tip block must be properly installed located
14-13/16" above the floor on which the appliance
will sit. The 6" Anti-Tip block must be provided
by the installer. See figure
1
. The Anti-Tip block
prevents serious injury that might result from
spilled hot liquids.
36"
counter-
top
height
24"
cabinet min.
22
¹⁄₈
"
opening
14
¹³₁₆
"
opening
Allow
⁷₁₆
"
overlap
Allow ¾"
overlap.
Allow ¾"
overlap.
19" to top
of floor
4"
5"
Electrical outlet location
Anti-Tip
block
Floor must
support
100 lbs.
14
¹³₁₆
"
to bottom
of Anti-Tip
block
3
¹⁄₂
"
(6")
23 ½"
min depth
Allow
³₁₆
"
overlap
21
¹⁹⁄₃₂
"
23
³⁄₈
"
14
¹⁹⁄₃₂
"
1
³⁄₄
"
door thickness
15
⁵⁄₈
"
23
⁷⁄₈
"
15"
auto drawer
opening
1
²³⁄₃₂
"
4
¹¹⁄₁₆
"
DRAWERMICRO OVEN MEASUREMENTS:
Figures
1
and
2
contain many DrawerMicro Oven measurements for reference
when planning the drawer’s location which can be installed
below any electric or gas wall oven. It can also be installed
using an electrical outlet in an adjacent cabinet within the
area where the provided electrical cord can reach. Power cord
access hole in cabinet should be a minimum 1½" diameter hole
and deburred of all sharp edges.
IMPORTANT:
Always allow sufficient power cord length to the
electrical outlet to prevent tension.
DO NOT USE AN EXTENSION CORD. If the power supply cord
is too short, have a qualified electrician or serviceman install
an outlet near the appliance.
Always check electrical codes for requirements.
Clearances and Dimensions
2
1