Viking VWH4848SS Installation Instructions - Page 7
VWH 18H. T-Series Wall Hoods - range hood
View all Viking VWH4848SS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Dimensions & Specifications (VWH 18"H. T-Series Wall Hoods 36", 48", & 60") Seal joints with silicone. Provided on "T" Series only. (15.62"cm) A (Hood width) 36"W. 35-7/8" (91.1 cm) A 48"W. 47-7/8" (121.6 cm) 60"W. 59-7/8" (152.1 cm) (682.67"cm) (301.52"cm) (451.78"cm) NOTE: Optional duct cover sold separately. VWH 18"H. T-Series Wall Hoods Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size 36" 35-7/8" (91.1 cm) 2 2 VINV1200* DEV1200*/1500** DIL1200 48" 47-7/8" (121.6 cm) 12" (30.5 cm) 12" (30.5 cm) 3 3 VINV1200* DEV1200*/1500** DIL1200 10" (25.4 cm) 60" 59-7/8" (152.1 cm) 4 4 VINV1200* DEV1200*/1500** DIL1200 Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-Line-Maximum amps 9.0 6.1/6.8 7.9 10" (25.4 cm) 11.4 8.4/9.1 10.2 11.8 8.8/9.5 10.6 * A 1,200 CFM interior- or exterior-power ventilator should be used with all T-Series models and when indoor models are installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods. 12 Clearance Dimensions (VWH 18"H. T-Series Wall Hoods) (45.71c8m") 7((6112668"72"t..mo69mccaimmnx.)). (913.46"cm) D+(1I14M.-41"c/Xm2"") (682.67"cm) 3(3(796061".".t42mmocciammnx.)). Note: T-Series Models must be installed in a covered, non-enclosed area, and should be protected from the elements as much as possible. The bottom of the hood should be 30" (76.2 cm) to 36" (91.4 cm) above the grill surface. The hood should be installed 4-1/2" (11.4 cm) plus the distance between the back trim and surface from the back wall. (Note: There is a 3" minimum clearance from the back trim to non-combustible surfaces, and a 24" minimum to combustible surfaces.) This will require building the hood out from the wall. Any combustible material used for this purpose must be covered with locally-supplied stainless steel. Viking also recommends using a backsplash. 13