PDP DISPLAY NOTHINGComposite 1 on PIP without screen, PDP DISPLAY NOTHINGComposite 1 without screen - base
View all Vizio VP50HDTV10A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
PDP DISPLAY NOTHING(Composite 1 without screen) BLOCK 1 No Is picture on screen? Check C310,R275,R274 Is there signal? Yes No No Check Q28's emitter. Is there signal? Check Q28's Base. No Is there signal? Check collector voltage(+5V). Use GProbe connect No from main to PC. Does scaler detect the signal? Q13 fail Yes Q28 fail Check: 1.C309 (signal AC coupled) 2.R276 3.R279(75ohm impedance) Is there signal? No Check input source PDP DISPLAY NOTHING(Composite 1 on PIP without screen) BLOCK 1 No No No Check Q28's Base. No Is picture on screen? Check C308,R273,R274 Is there signal? Check Q28's emitter. Is there signal? Is there signal? Check collector voltage(+5V). Yes Use GProbe connect No from main to PC. Does scaler detect the signal? Q10 fail Yes Q28 fail Check: 1.C309 (signal AC coupled) No 2.R276 Check input source 3.R279(75ohm impedance) Is there signal? 7 CONFIDENTIAL - DO NOT COPY Page 9-12 File No. SG-0219