• MAINTENANCE AND TROUBLE-SHOOTING MONITOR CARE Keep the monitor out of direct sunlight or the LCD display may be damaged. The monitor can be cleaned using a soft, dry cloth. Do not allow liquid to come in contact with the monitor. Remove the batteries when storing the CARDIOGLIDE 950. REPLACING THE BATTERIES If the display of the Monitor (1) becomes dim, the two L1154 watch batteries should be replaced. Remove the #8 x 1/2" Screw (16) from the back of the Monitor. Remove the two screws from the back cover of the Monitor and remove the back cover. Push the two old batteries out of the clips, and insert two new batteries. 6 Reattach the back cover and reattach the Monitor (1) to the Frame (6). Make sure that the wire on the Monitor is plugged into the sensor wire. Insert any excess wire into the Frame. Make sure not to pinch the wire between the Frame and the Monitor. Screws Batteries 16 4e 5 ADJUSTING THE MAGNET AND REED SWITCH If the monitor does not function properly, the Magnet (27) and Reed Switch (15) should be checked. Pivot the Pedal Frame (7) until the Magnet is aligned with the Reed Switch. Loosen the #8 x 3/4" Screw (35) and adjust the position of the Reed Switch so that there is a 1/8" gap between the Magnet and the Reed Switch. Retighten the #8 x 3/4" Screw. 7 27 15 15 35 27 LUBRICATING THE CARDIOGLIDE 950 The ends of the Link Arms (4) should be oiled every six months. Apply a few drops of light multi-purpose oil (not included) between the Link Arms and the dome caps in the indicated locations. Apply Oil 4 8