Weslo Daybreak 410 Spa English Manual - Page 8

Assembly

Page 8 highlights

Assembly Before beginning assembly, carefully read the following information and instructions: • Place all parts in a cleared area and remove the packing materials from the spa shell. Do not dispose of the packing materials until assembly is completed and the spa is operating. • During assembly, make sure that all parts are oriented as shown in the drawings. • Read each assembly step before you begin. • Tighten all parts as you assemble them, unless instructed to do otherwise. ASSEMBLY REQUIRES THE FOLLOWING TOOLS (not included): • One phillips screwdriver • You may also need a small amount of soap or water. A wire connector is provided on the controller of the spa to connect a minimum No. 8 AWG (8.04 mm2) solid copper conductor between the spa and any metal equipment, electrical enclosure made of metal, metal water pipes, or conduit within five feet of the spa. 1. Before beginning assembly, make sure that you 1 have read and understand the information in the box above and on the previous two pages. Refer to the drawing on page 6 and locate the Access Panel (2). (Note: The slats on the Access Panel are narrower than the slats on the rest of the spa.) Remove the four #10 x 2" Sheet Metal Screws (7) from the Access Panel. Remove the Access Panel by sliding it down and then pulling the bottom of it away from the spa. Be careful not to damage the spa shell. Remove the end of the power cord and the GFCI from inside the spa. 2 7 Power Cord with GFCI 2. Locate the drain hose inside the spa. Close the valve knob on top of the drain hose. Next, make sure that the cap is fully tightened onto the end of the drain hose. Refer to the inset drawing. Locate the two gate valves inside the spa-there is one gate valve on each side of the access opening. Make sure that the gate valves are open. Refer to step 1 above. Re-attach the Access Panel (2) to the spa with the four #10 x 2" Sheet Metal Screws (7). Make sure that the two collars on the heater and the two collars on the pump are tightened. 2 Collars Gate Valve Collars Cap Valve Knob Drain Hose 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

8
2.
Locate the drain hose inside the spa. Close the
valve knob on top of the drain hose. Next, make
sure that the cap is fully tightened onto the end of
the drain hose.
Refer to the inset drawing. Locate the two gate
valves inside the spa—there is one gate valve on
each side of the access opening. Make sure that the
gate valves are open.
Refer to step 1 above. Re-attach the Access Panel
(2) to the spa with the four #10 x 2” Sheet Metal
Screws (7).
Make sure that the two collars on the heater and the
two collars on the pump are tightened.
Before beginning assembly, carefully read the
following information and instructions:
Place all parts in a cleared area and remove the
packing materials from the spa shell. Do not dis-
pose of the packing materials until assembly is
completed and the spa is operating.
During assembly, make sure that all parts are
oriented as shown in the drawings.
Read each assembly step before you begin.
Tighten all parts as you assemble them, unless
instructed to do otherwise.
ASSEMBLY REQUIRES THE FOLLOWING
TOOLS (not included):
• One phillips screwdriver
• You may also need a small amount of soap
or water.
A wire connector is provided on the controller
of the spa to connect a minimum No. 8 AWG
(8.04 mm
2
) solid copper conductor between the
spa and any metal equipment, electrical enclo-
sure made of metal, metal water pipes, or con-
duit within five feet of the spa.
1.
Before beginning assembly, make sure that you
have read and understand the information in the
box above and on the previous two pages.
Refer to the drawing on page 6 and locate the
Access Panel (2).
(Note: The slats on the Access
Panel are narrower than the slats on the rest of
the spa.)
Remove the four #10 x 2” Sheet Metal
Screws (7) from the Access Panel. Remove the
Access Panel by sliding it down and then pulling the
bottom of it away from the spa.
Be careful not to
damage the spa shell.
Remove the end of the power cord and the GFCI
from inside the spa.
Assembly
Power Cord
with GFCI
Drain
Hose
Valve
Knob
Cap
Collars
Collars
7
2
1
2
Gate Valve