Whirlpool EED4100WQ Installation Instructions - Page 3
Installation Requirements - parts
View all Whirlpool EED4100WQ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Location Requirements ■■ Flat-blade screwdriver ■■ #2 Phillips head screwdriver ■■ Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench (for adjusting dryer feet) ■■ Level ■■ Wire stripper (direct wire installations) ■■ Utlility knife ■■ 1/4" nut driver (recommended) ■■ Vent clamps ■■ Caulking gun and compound (for installing new exhaust vent) ■■ Tin snips (new vent installations) ■■ Tape measure ■■ Pliers Parts supplied: Parts package is located in dryer drum. Check that all parts are included. 4 Leveling legs Parts needed: Check local codes. Check existing electrical supply and venting, and read "Electrical Requirements" and "Venting Requirements" before purchasing parts. Mobile home installations require metal exhaust system hardware, available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the "Assistance or Service" section of the Dryer User Instructions. If using a power supply cord: Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain: ■■ A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends. ■■ A UL listed strain relief. You will need: ■■ A location allowing for proper exhaust installation. See "Venting Requirements." ■■ A separate 30 amp circuit. ■■ If you are using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See "Electrical Requirements." ■■ A sturdy floor to support the total weight (dryer and load) of 200 lbs. (90.7 kg). The combined weight of a companion appliance should also be considered. ■■ Level floor with maximum slope of 1" (25 mm) under entire dryer. (If slope is greater than 1" [25 mm], install Extended Dryer Feet Kit, Part Number 279810.) If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly. Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. 3