Whirlpool GC3NHAXVB Use and Care Guide - Page 10
Product Data Sheets
UPC - 883049124186
View all Whirlpool GC3NHAXVB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
PRODUCT DATA SHEETS Base Grille Water Filtration System Model T1WB2L/T1RFWB2 Capacity 200 Gallons (758 Liters) Model T1WB2/T1RFWB2 Capacity 200 Gallons (758 Liters) Tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane, Tetrachloroethylene, Endrin, Alachlor, Monochlorobenzene and Ethylbenzene. This system has been tested according to NSF/ANSI 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53. Substance Reduction Aesthetic Effects Chlorine Taste/Odor Particulate Class I* Contaminant Reduction Lead: @ pH 6.5 Lead: @ pH 8.5 Mercury: @ pH 6.5 Mercury: @ pH 8.5 Benzene O-Dichlorobenzene Toxaphene Atrazine Asbestos Live Cysts‡ Turbidity Alachlor Endrin Ethylbenzene Lindane Monochlorobenzene Tetrachloroethylene NSF Reduction Requirements 50% reduction 85% reduction NSF Reduction Requirements 0.010 mg/L 0.010 mg/L 0.002 mg/L 0.002 mg/L 0.005 mg/L 0.6 mg/L 0.003 mg/L 0.003 mg/L 99% >99.95% 0.5 NTU 0.002 mg/L 0.002 mg/L 0.7 mg/L 0.002 mg/L 0.6 mg/L 0.005 mg/L Average Influent 2.0 mg/L 3533333#/mL Average Influent 150 ug/L 157 ug/L 0.0058 mg/L 0.0057 mg/L 15 ug/L 1750 ug/L 15 ug/L 10 ug/L 101 MFL 120,000/L 11.4 NTU 41.3 ug/L 5.9 ug/L 1867 ug/L 1.9 ug/L 2.0 ug/L 14.2 ug/L Influent Challenge Concentration Maximum Effluent 2.0 mg/L ± 10% 0.08 mg/L At least 10,000 particles/mL 22000 #/mL** Influent Challenge Concentration Maximum Effluent 0.15 mg/L ± 10% 0.15 mg/L ± 10% 1.0 ug/L 2.0 ug/L 0.006 mg/L ± 10% 0.006 mg/L ± 10% 0.0002 mg/L 0.0002 mg/L 0.015 mg/L ± 10% 0.5 ug/L 1.8 ± 10% 1.0 ug/L 0.015 ± 10% 1.0 ug/L 0.009 mg/L ± 10% 2 ug/L 107 to 108 fibers/L†† 0.17 MFL 50,000/L min. 11 ± 1 NTU 8/L‡ 0.41 NTU 0.04 ± 10% 0.2 ug/L 0.006 ± 10% 0.5 ug/L 2.1 ± 10% 0.70 ug/L 0.002 ± 10% 0.02 ug/L 2.0 ± 10% 0.0005 ug/L 0.015 ± 10% 0.5 ug/L Average Effluent 2.0 mg/L 11567 #/mL Average Effluent 1 ug/L 1.08 ug/L 0.0002 mg/L 0.0002 mg/L 0.5 ug/L 1.0 ug/L 1.0 ug/L 2 ug/L 0.17 MFL 1/L‡ 0.24 NTU 0.2 ug/L 0.3 ug/L 0.0588 ug/L 0.02 ug/L 0.0005 ug/L 0.5 ug/L Minimum % Reduction 95.93 99.38 Minimum % Reduction 99.33 98.72 96.53 96.5 96.67 99.94 93.33 80.8 99.83 99.99 96.4 99.52 91.5 99.96 98.93 99.98 96.47 Average % Reduction 97.36 99.67 Average % Reduction 99.33 99.31 96.53 96.5 96.67 99.94 93.33 80.8 99.83 >99.99 97.89 99.52 95.47 100 98.93 99.98 96.47 Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). s It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. s Use replacement cartridge T1RFWB2, part #4396710. 2006 suggested retail price of $39.99 U.S.A./$49.99 Canada. Prices are subject to change without notice. Model T1WB2L: Style 1 - When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter. Style 2 - When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter. Model T1WB2: Change the water filter cartridge every 6 months depending upon your usage. If the water flow to the water dispenser or ice maker decreases noticeably before 6 months have passed, replace the water filter cartridge more often. s These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary. s The product is for cold water use only. s Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. s Refer to the back cover or "Accessories" section for the Manufacturer's name, address and telephone number. s Refer to the "Warranty" section for the Manufacturer's limited warranty. Application Guidelines/Water Supply Parameters Water Supply Water Pressure Water Temperature Service Flow Rate City or Well 30 - 120 psi (207 - 827 kPa) 33° - 100°F (0.6° - 37.8°C) 0.5 gpm (1.9 L/min.) @ 60 psi. *Class I particle size: >0.5 to