® Ice Maker PRODUCT MODEL NUMBERS GI15NDXT GI15NFLT GI15NFRT Electrical: 115 volt, 60 Hz, AC only, 15 or 20-amp grounded circuit is required. A time-delay fuse or circuit breaker and separate circuit is recommended. Water: A cold water supply with water pressure of between 30 and 120 psi (207 and 827 kPa) is required. Drain: Either a gravity-drain system or condensate pump to carry water to an existing drain. CABINET OPENING DIMENSIONS A. Recommended location for electrical and plumbing fixtures. B. Floor level 34" (86.4 cm) Min. 34¹⁄₂ " (87.6 cm) Max. 11¹⁄₂ " (29.2 cm) 3¹⁄₂ " 9" (8.9 cm) (22.9 cm) 24" (60.1 cm) A 28¹⁄₂ " (72.4 cm) B DRAIN REQUIREMENTS 15" (38.1 cm) RERAERARVIVEIWEW A B C A. Drain hose (drain pump models only) B. Vent hose (drain pump models only) C. Water supply line SIDE VIEW 3⁵⁄₈" (9.2 cm) A B 1" (2.54 cm) 23" C (58.4 cm) D 2" - 1¹⁄₂" (5 cm - 3.8 cm) ■ Drain lines must have a minimum of 5⁄8" (15.88 mm) inside diameter. ■ Drain lines must have a 1" drop per 48" (2.54 cm drop per 122 cm) of run or 1⁄4" drop per 12" (6.35 mm per 30.48 cm) of run and must not have low points where water can settle. ■ The floor drains must be large enough to accommodate drainage from all drains. ■ The ideal installation has a standpipe with a 1-1⁄2" (3.81 cm) to 2" (5.08 cm) PVC drain reducer installed directly below the outlet of the drain tube as shown. You must maintain a 1" (2.54 cm) air gap between the drain hose and the standpipe. ■ It may be desirable to insulate the drain line thoroughly up to the drain inlet. A. Drain hose B. 1" (2.54 cm) air gap C. PVC drain reducer D. Center of drain should be 23" (58.4 cm) from front of door, with or without the ³⁄₄" (1.91 cm) panel on the door. The drain should also be centered from left to right (7 18.58 cm] from either side of the ice maker). Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Ref. 2313683 03-02-07

  • 1

PRODUCT MODEL NUMBERS
CABINET OPENING DIMENSIONS
GI15NDXT
GI15NFLT
GI15NFRT
Electrical:
115 volt, 60 Hz, AC only, 15 or
20-amp grounded circuit is required. A time-delay
fuse or circuit breaker and separate circuit is
recommended.
Water:
A cold water supply with water pressure
of between 30 and 120 psi (207 and 827 kPa) is
required.
Drain:
Either a gravity-drain system or
condensate pump to carry water to an existing
drain.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only.
For complete details, see Installation
Instructions packed with product.
Specifications subject to change without notice.
Ref. 2313683
03-02-07
®
11
¹⁄₂
"
(29.2 cm)
15"
A
B
(38.1 cm)
24"
(60.1 cm)
9"
(22.9 cm)
28
¹⁄₂
"
(72.4 cm)
34"
(86.4 cm)
Min.
34
¹⁄₂
"
(87.6 cm)
Max.
3
¹⁄₂
"
(8.9 cm)
A. Recommended location for electrical
and plumbing fixtures.
B. Floor level
3
⁵⁄₈
"
(9.2 cm)
23"
(58.4 cm)
2" - 1
¹⁄₂
"
(5 cm - 3.8 cm)
1" (2.54 cm)
A
D
C
B
A. Drain hose
B. 1" (2.54 cm) air gap
C. PVC drain reducer
D. Center of drain should be 23" (58.4 cm) from front of door,
with or without the
³⁄₄
" (1.91 cm) panel on the door. The
drain should also be centered from left to right (7
⁵⁄₁₆
"
[18.58 cm] from either side of the ice maker).
Drain lines must have a minimum of 5⁄8"
(15.88 mm) inside diameter.
Drain lines must have a 1" drop per 48" (2.54 cm
drop per 122 cm) of run or 1⁄4" drop per 12"
(6.35 mm per 30.48 cm) of run and must not
have low points where water can settle.
The floor drains must be large enough to
accommodate drainage from all drains.
The ideal installation has a standpipe with a 1-1⁄2"
(3.81 cm) to 2" (5.08 cm) PVC drain reducer
installed directly below the outlet of the drain tube
as shown. You must maintain a 1" (2.54 cm) air
gap between the drain hose and the standpipe.
It may be desirable to insulate the drain line
thoroughly up to the drain inlet.
DRAIN REQUIREMENTS
A. Drain hose (drain pump models only)
B. Vent hose (drain pump models only)
C. Water supply line
A
C
B
REAR VIEW
SIDE VIEW