Make Electrical Connection WARNING 5. Use UL listed wire connectors and connect black wires (C) together. 6. Use UL listed wire connectors and connect white wires (E) together. WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Disconnect power. 2. Remove terminal box cover. 3. Remove the knockout in the terminal box cover and install a UL listed or CSA approved ¹⁄₂" strain relief. A B Electrical Shock Hazard Electrically ground blower. Connect ground wire to green and yellow ground wire in terminal box. Failure to do so can result in death or electrical shock. 7. Connect green (or bare) ground wire from home power supply to yellow-green ground wire (E) in terminal box using UL listed wire connectors. 8. Tighten strain relief screw. 9. Install terminal box cover. 10. Check that all light bulbs are secure in their sockets. 11. Reconnect power. Install Duct Covers 1. Attach the vertical duct cover supports using 4 - 4 x 8 mm screws. A. Knockout B. Terminal box cover 4. Run home power supply cable through strain relief, into terminal box. A B C D A B A A. Screws B. Vertical duct cover support 2. Slide upper duct covers into place until springs "click." E F A. Home power supply cable B. UL listed or CSA approved strain relief C. Black wires D. UL listed wire connectors E. White wires F. Green (or bare) and yellow-green ground wires A B A. Upper duct cover B. Spring 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

9
Make Electrical Connection
1.
Disconnect power.
2.
Remove terminal box cover.
3.
Remove the knockout in the terminal box cover and install a
UL listed or CSA approved
¹⁄₂
" strain relief.
4.
Run home power supply cable through strain relief, into
terminal box.
5.
Use UL listed wire connectors and connect black wires (C)
together.
6.
Use UL listed wire connectors and connect white wires (E)
together.
7.
Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (E) in terminal box using UL listed
wire connectors.
8.
Tighten strain relief screw.
9.
Install terminal box cover.
10.
Check that all light bulbs are secure in their sockets.
11.
Reconnect power.
Install Duct Covers
1.
Attach the vertical duct cover supports using 4 - 4 x 8 mm
screws.
2.
Slide upper duct covers into place until springs “click.”
A. Knockout
B. Terminal box cover
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-green ground wires
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
A
B
C
D
E
F
A. Screws
B. Vertical duct cover support
A. Upper duct cover
B. Spring
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
B
A
A
B
A