Whirlpool GXW6530DXS Use & Care Guide - Page 8
Install Range Hood, Connect Vent System - recirculating kit
View all Whirlpool GXW6530DXS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Install Range Hood 1. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of hood. C B 2. Measure from the bottom of the air deflector to the bottom of the hood outlet. A B X C D E A A. Mounting screws B. Mounting slots C. Lower mounting screws 2. Remove the grease filter. See "Range Hood Care" section. 3. Level the range hood and tighten upper mounting screws. 4. Install 2 - 5 x 45 mm lower mounting screws and tighten. Connect Vent System For vented installations only: 1. Fit vent system over the exhaust outlet. 2. Seal connection with clamps. 3. Check that backdraft dampers work properly. For non-vented (recirculating) installation only: 1. Assemble the air deflector with the duct cover bracket with 4 - assembly screws provided with the Recirculation Kit. A. Air deflector B. Vent clamp C. X = length to cut vent duct D. Vent duct E. Exhaust outlet 3. Cut the duct to the measured size (X). 4. Remove the air deflector. 5. Slide the duct onto the bottom of the air deflector. 6. Place the assembled air deflector and duct over the exhaust outlet from the hood. 7. Reassemble the air deflector to the duct cover bracket with 4 assembly screws. 8. Seal connections with vent clamps. A B C A. Assembly screws B. Air deflector C. Duct cover bracket 8