Whirlpool GXW7330DXS Use & Care Guide - Page 11

Non-Vented recirculating Installation Filters, Replacing a Fluorescent Lamp

Page 11 highlights

Non-Vented (recirculating) Installation Filters: The charcoal filter is not washable. It should last up to 6 months with normal use. Replace with Charcoal Filter Kit Number W10294730. To replace charcoal filter: 1. Remove metal grease filter from range hood. See "Metal Grease Filter" in this section. 2. Bend spring clips away from metal grease filter. Replacing a Fluorescent Lamp Turn off the range hood and allow the fluorescent lamp to cool. If new light does not operate, make sure the lamp is inserted correctly before calling service. 1. Disconnect power. 2. Remove the screw from the lens cover and remove the cover. 3. Place charcoal filter into top side of metal filter. 4. Bend spring clips back into place to secure the charcoal filter to the metal filter. C A B A. Screw B. Lens cover C. Fluorescent lamp 3. Remove the light from the socket and replace with a 120-volt, 13-watt (maximum), 50° fluorescent light with a GX24 base. 4. Replace the lens cover and screw. Tighten the screw. 5. Reconnect power. 5. Replace metal grease filter. See "Metal Grease Filter" in this section. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

11
Non-Vented (recirculating) Installation Filters:
The charcoal filter is not washable. It should last up to 6 months
with normal use. Replace with Charcoal Filter Kit Number
W10294730.
To replace charcoal filter:
1.
Remove metal grease filter from range hood. See “Metal
Grease Filter” in this section.
2.
Bend spring clips away from metal grease filter.
3.
Place charcoal filter into top side of metal filter.
4.
Bend spring clips back into place to secure the charcoal filter
to the metal filter.
5.
Replace metal grease filter. See “Metal Grease Filter” in this
section.
Replacing a Fluorescent Lamp
Turn off the range hood and allow the fluorescent lamp to cool.
If new light does not operate, make sure the lamp is inserted
correctly before calling service.
1.
Disconnect power.
2.
Remove the screw from the lens cover and remove the cover.
3.
Remove the light from the socket and replace with a 120-volt,
13-watt (maximum), 50° fluorescent light with a GX24 base.
4.
Replace the lens cover and screw. Tighten the screw.
5.
Reconnect power.
A. Screw
B. Lens cover
C. Fluorescent lamp
A
B
C