Whirlpool GXW7330DXS Installation Guide - Page 7

Installation Instructions - canopy range hood

Page 7 highlights

INSTALLATION INSTRUCTIONS Prepare Location ■ It is recommended that the vent system be installed before hood is installed. 9. Drill 4.8 mm) pilot holes at all locations where screws are being installed into wood. ■ Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent. ■ Check your ceiling height and the hood height maximum before you select your hood. 1. Disconnect power. 10. Install the 2 - 5 x 45 mm mounting screws. Leave a ¹⁄₄" (6.4 mm) gap between the wall and the back of the screw head to slide range hood into place. ¹⁄₄" (6.4 mm) 2. Determine which venting method to use: roof, wall, or nonvented. 3. Select a flat surface for assembling the range hood. Place covering over that surface. Vent Cover Support Bracket Installation WARNING Excessive Weight Hazard Use two or more people to move and install range hood. Installations using telescoping upper and lower vent cover assembly 1. Position vent cover bracket on wall about ¹⁄₈" (3.0 mm) away from the ceiling. 2. Mark the hole locations. Failure to do so can result in back or other injury. 3. Drill ³⁄₈" (9.5 mm) holes for wall anchors and insert anchors flush with the wall. 4. Using 2 or more people, lift range hood onto covered surface. A C Range Hood Mounting Screws Installation 5. Determine and mark the centerline on the wall where the canopy hood will be installed. 6. Select a mounting height between a minimum of 24" (61.0 cm) for an electric cooking surface, a minimum of 27" (68.6 cm) for a gas cooking surface, and a suggested maximum of 36" (91.4 cm) above the range to the bottom of the hood. Mark a reference line on the wall. 7. Tape template in place, aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall. B D A. 8 x 40 mm drywall anchors B. Centerline on wall C. Vent cover support bracket D. 5 x 45 mm screws 4. Attach vent cover support bracket to wall. Complete Preparation A DRILL2 (TW O)3/16"PILOT HOLES THROUGH STUDS OR REAR W ALLSUPPORT Vertical Centerline REAR W ALL M OUNTING TEM PLATE HorizontalLine CL ALIGN BOTTOM EDGE W ITH PENCILLINE INDICATING BOTTOM OFTHE HOOD Installation Height B C A. Centerline B. Fastener locations C. Mounting height reference 1. Determine and make all necessary cuts in the wall for the vent system. Install the vent system before installing the hood. See "Venting Requirements" section. 2. Determine the required height for the home power supply cable and drill a 1¼" (3.2 cm) hole at this location. 3. Run the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordinances. There must be enough ½" conduit and wires from the fused disconnect (or circuit breaker) box to make the connection in the hood's electrical terminal box. NOTE: Do not reconnect power until installation is complete. 4. Use caulk to seal all openings. 8. Mark centers of the fastener locations through the template to the wall. IMPORTANT: All screws must be installed into wood. If there is no wood to screw into, additional wall framing supports may be required. Remove the template. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

7
INSTALLATION INSTRUCTIONS
Prepare Location
It is recommended that the vent system be installed before
hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum
before you select your hood.
1.
Disconnect power.
2.
Determine which venting method to use: roof, wall, or non-
vented.
3.
Select a flat surface for assembling the range hood. Place
covering over that surface.
4.
Using 2 or more people, lift range hood onto covered surface.
Range Hood Mounting Screws Installation
5.
Determine and mark the centerline on the wall where the
canopy hood will be installed.
6.
Select a mounting height between a minimum of
24" (61.0 cm) for an electric cooking surface, a minimum
of 27" (68.6 cm) for a gas cooking surface, and a suggested
maximum of 36" (91.4 cm) above the range to the bottom
of the hood. Mark a reference line on the wall.
7.
Tape template in place, aligning the template centerline and
bottom of template with hood bottom line and with the
centerline marked on the wall.
8.
Mark centers of the fastener locations through the template
to the wall.
IMPORTANT:
All screws must be installed into wood. If there
is no wood to screw into, additional wall framing supports
may be required.
Remove the template.
9.
Drill
³⁄₁₆
" (4.8 mm) pilot holes at all locations where screws are
being installed into wood.
10.
Install the 2 - 5 x 45 mm mounting screws. Leave a
¹⁄₄
" (6.4 mm) gap between the wall and the back of the screw
head to slide range hood into place.
Vent Cover Support Bracket Installation
Installations using telescoping upper and lower vent cover
assembly
1.
Position vent cover bracket on wall about
¹⁄₈
" (3.0 mm) away
from the ceiling.
2.
Mark the hole locations.
3.
Drill
³⁄₈
" (9.5 mm) holes for wall anchors and insert anchors
flush with the wall.
4.
Attach vent cover support bracket to wall.
Complete Preparation
1.
Determine and make all necessary cuts in the wall for the vent
system. Install the vent system before installing the hood. See
“Venting Requirements” section.
2.
Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
3.
Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough ½" conduit and wires from
the fused disconnect (or circuit breaker) box to make the
connection in the hood’s electrical terminal box.
NOTE:
Do not reconnect power until installation is complete.
4.
Use caulk to seal all openings.
A. Centerline
B. Fastener locations
C. Mounting height reference
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
Vertical Centerline
C
L
L
L
A
W
R
A
E
R
E
T
A
L
P
M
E
T
G
N
I
T
N
U
O
M
E
G
D
E
M
O
T
T
O
B
N
G
I
L
A
E
N
I
L
L
I
C
N
E
P
H
T
I
W
M
O
T
T
O
B
G
N
I
T
A
C
I
D
N
I
D
O
O
H
E
H
T
F
O
t
h
g
i
e
H
n
o
i
t
a
l
l
a
t
s
n
I
T
R
O
P
P
U
S
L
L
A
W
R
A
E
R
R
O
S
D
U
T
S
H
G
U
O
R
H
T
S
E
L
O
H
T
O
L
I
P
"
6
1
/
3
)
O
W
T
(
2
L
L
I
R
D
e
n
i
L
l
a
t
n
o
z
i
r
o
H
A
C
B
A. 8 x 40 mm drywall anchors
B. Centerline on wall
C. Vent cover support bracket
D. 5 x 45 mm screws
¹⁄₄
"
(6.4 mm)
A
B
C
D