Whirlpool LDR3822P Owners Manual 1 - Page 6
Location Requirements
View all Whirlpool LDR3822P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Location Requirements WARNING � For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required for vented models. Louvered doors with equivalent ventilation openings are acceptable. � Companion appliance spacing should also be considered. Recommended installation clearances (dryer only): Recessed or closet installation - Dryer only Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. Do not dry anything that has ever had anything flammable on it (even after washing). Place dryer at least 18 inches (460 mm) above the floor for a garage installation. Failure to do so can result in death, explosion, or fire. Check code requirements. Some codes limit, or do not permit, installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. You will need: � A location allowing for proper exhaust installation. See "Venting Requirements." � A 120 V, 60 Hz, AC-only, 15 A or 20 A circuit. � A grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See "Electrical Requirements." � A sturdy floor to support the dryer weight (dryer and load) of 115 lbs. (52 kg). The combined weight of a companion appliance should also be considered. � Level floor with a maximum slope of 1" (25 mm) under the entire dryer. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly. � For garage installation, place dryer at least 18" (460 mm) above the floor. If using a pedestal, you will need 18" (460 mm) to bottom of the dryer. � The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. IMPORTANT: Do not operate dryer at temperatures below 45°F (7°C). Lower temperatures may cause dryer not to shut off at end of automatic cycles, resulting in longer drying times. Installation clearances: For each arrangement, consider allowing more space for ease of installation and servicing, spacing for companion appliances, and clearances for walls, doors, and floor moldings. Space must be large enough to allow the dryer door to fully open. Add spacing on all sides of the dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in the door are required. Installation spacing for a recessed area or closet installation All dimensions show recommended and minimum spacing allowed. � Additional spacing should be considered for ease of installation and servicing. � Additional clearances might be required for wall, door, floor, moldings and dryer venting. � Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer. Recessed area Closet door with vents Recessed or closet installation - Stacked Recessed area Closet door with vents *Additional spacing recommended. Most installations require a minimum 5 1/2" (140 mm) clearance behind the dryer for the exhaust vent with elbows. See "Venting Requirements." 6