Whirlpool LER4634PT Installation Instructions - Page 10

Install Vent System, Install Leveling Legs, Level Dryer, Connect Vent, Reverse Door Swing (Optional

Page 10 highlights

Vent Length Chart Number of 90º turns or elbows Type of vent Box or Louvered hoods Angled hoods 0 Rigid metal 64 ft (20 m) 58 ft (17.7 m) Flexible metal 36 ft (11 m) 28 ft (8.5 m) 1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m) Flexible metal 31 ft (9.4 m) 23 ft (7 m) 2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m) Flexible metal 27 ft (8.2 m) 19 ft (5.8 m) 3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m) Flexible metal 25 ft (7.6 m) 17 ft (5.2 m) 4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m) Flexible metal 23 ft (7 m) 15 ft (4.6 m) Install Vent System 1. (Optional) Put on safety glasses and gloves. 2. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood. 3. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4 in. (10.2 cm) clamp. 4. Run vent to dryer location. Use the straightest path possible. See "Determine Vent Length." Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent. Install Leveling Legs WARNING Excessive Weight Hazard Use two or more people to move and install dryer. Failure to do so can result in back or other injury. 1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer. See illustration. 2. Firmly grasp the body of the dryer (not the top or console panel). 5. Place a carton corner post under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. 6. Leave enough room to connect the exhaust vent. Level Dryer Check the levelness of the dryer. Check levelness first side-to-side, then front-to-back. If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness. NOTE: It might be necessary to level the dryer again after it is moved into its final position. Connect Vent 1. Using a 4 in. (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Make sure the vent is secured to exhaust hood with a 4 in. (10.2 cm) clamp. 2. Move dryer into final position. Do not crush or kink vent. Make sure dryer is level. 3. (On gas models) If flexible metal tubing is used, check to be sure there are no kinks in the flexible gas line. Reverse Door Swing (Optional) You can change your door swing from a right-side opening to a left-side opening, if desired. Reversible Large Side-Swing Door 1 2 4 3 Gently lay the dryer on the cardboard corners. 3. Examine the leveling legs. Find the diamond marking. 1. Place towel (1) on top of dryer to protect surface. 2. Open dryer door. Remove bottom screws from cabinet side of hinges (3). Loosen (do not remove) top screws from cabinet side of hinges. 3. Lift door until top screws in cabinet are in large part of hinge slot. Pull door forward off screws. Set door on top of dryer. Remove top screws from cabinet. 4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

10
Vent Length Chart
Install Vent System
1.
(Optional) Put on safety glasses and gloves.
2.
Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
3.
Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4 in. (10.2 cm) clamp.
4.
Run vent to dryer location. Use the straightest path possible.
See
Determine Vent Length.
Avoid 90
º
turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure vent.
Install Leveling Legs
1.
To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer. See illustration.
2.
Firmly grasp the body of the dryer (not the top or console
panel).
Gently lay the dryer on the cardboard corners.
3.
Examine the leveling legs. Find the diamond marking.
4.
Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5.
Place a carton corner post under each of the 2 dryer back
corners. Stand the dryer up. Slide the dryer on the corner
posts until it is close to its final location.
6.
Leave enough room to connect the exhaust vent.
Level Dryer
Check the levelness of the dryer. Check levelness first
side-to-side, then front-to-back.
If the dryer is not level, prop up the dryer using a wood block. Use
a wrench to adjust the legs up or down and check again for
levelness.
NOTE:
It might be necessary to level the dryer again after it is
moved into its final position.
Connect Vent
1.
Using a 4 in. (10.2 cm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured to
exhaust hood with a 4 in. (10.2 cm) clamp.
2.
Move dryer into final position. Do not crush or kink vent. Make
sure dryer is level.
3.
(On gas models) If flexible metal tubing is used, check to be
sure there are no kinks in the flexible gas line.
Reverse Door Swing (Optional)
You can change your door swing from a right-side opening to a
left-side opening, if desired.
Reversible Large Side-Swing Door
1.
Place towel (1) on top of dryer to protect surface.
2.
Open dryer door. Remove bottom screws from cabinet side of
hinges (3). Loosen (do not remove) top screws from cabinet
side of hinges.
3.
Lift door until top screws in cabinet are in large part of hinge
slot. Pull door forward off screws. Set door on top of dryer.
Remove top screws from cabinet.
Number of
90º turns
or elbows
Type of
vent
Box or
Louvered
hoods
Angled
hoods
0
Rigid metal
Flexible metal
64 ft (20 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
1
Rigid metal
Flexible metal
54 ft (16.5 m)
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
2
Rigid metal
Flexible metal
44 ft (13.4 m)
27 ft (8.2 m)
38 ft (11.6 m)
19 ft (5.8 m)
3
Rigid metal
Flexible metal
35 ft (10.7 m)
25 ft (7.6 m)
29 ft (8.8 m)
17 ft (5.2 m)
4
Rigid metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1
2
3
4