Mark Hole Locations, Mark and Cut Vent Opening, Drill Electrical Opening
View all Whirlpool UXT4130ADS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
5. Mark Hole Locations 6. Mark and Cut Vent Opening 3¹⁄₄" x 10" (8.3 x 25.4 cm) Rectangular Vent System Lift the range hood into place and insert the mounting bracket tabs through the slots in the back of the range hood. 45˚+ AA 90˚ ■ Using a ¹⁄₂" (13 mm) drill bit, drill a hole in each of the dots marked previously on either the wall or upper cabinet. Using the outside edges of the holes, mark the vent opening. ■ Using a jigsaw or keyhole saw, cut the vent opening. 7. Drill Electrical Opening C CB D D Hold the range hood firmly in place with one hand and bend each mounting tab (A) upward approximately 90°. Mark the hole at the power supply knockout (B). For a non-vented (recirculating) installation: Go to Step 7. For a top vented installation: Mark the 4 vent hole locations (C) on the top of the range hood. For a rear vented installation: Mark the 4 vent hole locations (D) on the rear of the range hood. OPTIONAL: Mark the hole in each mounting tab. Remove the range hood and set it aside. Using a 1¹⁄₄" (3 cm) drill bit, drill the hole in the dot marked previously at the electrical strain relief. OPTIONAL: Using a ¹⁄₈" (3 mm) drill bit, drill pilot holes for the dots marked previously at each mounting tab at an approximate 45° angle in an upward direction. 7